Electrical connection
Leuze electronic GmbH + Co. KG
BCL 300
i
\ BCL 301
i
67
7.2.2 MK 300 terminal hood with spring-cage terminals
The MK 300 terminal hood makes it possible to connect the BCL 300
i
directly and without additional
connectors. The MK 300 features three cable lead-throughs in which the shielding connection for the inter
-
face cable is also located. The BCL 300
i
is also to be configured when the MK 300 is in a closed state via
a Mini-B type USB socket functioning as the service interface. Parameter memory is integrated into the
MK 300 which temporarily stores the settings of the BCL 300
i
in the case of replacement and transmits
them to a new device.
Figure 7.3: BCL 300
i
- MK 300 terminal hood with spring-loaded terminals
Cable fabrication and shielding connection
Remove approx. 78 mm of the connection cable sheathing. 15 mm of sheath of the shielded line must be
freely accessible.
Figure 7.4: Cable fabrication for MK 300 terminal hood
The shield is automatically contacted when the cable is lead into the metal screw fitting and fastened when
the cord grip is closed. Then lead the individual wires into the terminals according to the diagram. Wire end
sleeves are not necessary.
NOTE
The integrated parameter memory for the simple replacement of the BCL 300
i
is located in the
MK 300.
NOTE
Dimensioned drawing on see chapter 5.3.6 "Dimensioned drawings of MS 3xx / MK 3xx connec
Terminal hood
MK 300
SERVICE
2
1 3 5
4
GND
D+
D-
VB
ID
Mini-B USB socket
(behind protective cap)
Terminal block
PWR / SW IN/OUT
Terminal block HO
ST
/ B
US
IN
Terminal designation
MK 300
≈ 55 mm
≈ 8 mm
≈ 15 mm