Starting the device
Connect the +18 … 30VDC supply voltage (typ. +24VDC); the BCL 300
i
\ BCL 301
i
starts up.
The PWR and NET LEDs display the device status.
PWR LED
green, flashing
Device ok, initialization phase
Green, continuous light
Power On, device OK
green, briefly off - on
Good read, successful reading
green, briefly off -
briefly red - on
No read, reading not successful
Orange, continuous light
Service mode
red, flashing
Warning set
Red, continuous light
Error, device error
NET LED
flashes green
Initialization
Green, continuous light
Bus operation ok
flashes red
Communication error
Red, continuous light
Bus error
If a display is available, the following information appears successively during startup:
•
Startup
• Device designation e.g.
BCL 301i SM 102 D
•
Reading Result
If
Reading Result
is displayed, the device is ready.
Stand-alone operation BCL 300
i
After voltage (18 … 30VDC) has been connected to the switching input, a read process is activated. In the
standard setting, all common code types for decoding are released; only the 2/5 Interleaved code type is
limited to 10 digits of code content.
If a code is lead through the reading field, the code content isdecoded and output via the connected inter
-
face.
The standard protocol for this is: 9600 Baud, 8 data bits, no parity, 1 stop bit.