Diagnostics and troubleshooting
Leuze electronic
AMS 301
i
55
TNT
35/7-2
4
V
10
Diagnostics and troubleshooting
10.1
Service and diagnostics in the display of the AMS 301
i
In the main menu of the AMS 301
i
, expanded "Diagnostics" can be called up under the
Service
heading.
From the
Service
main menu, press the enter button
to access the underlying menu
level.
Use the up/down buttons
to select the corresponding menu item in the selected level;
use the enter button
to activate the selection.
Return from any sub-level to the next-higher menu item by pressing the ESC button
.
10.1.1
Status messages
The status messages are written in a ring memory with 25 positions. The ring memory is
organized according to the FIFO principle. No separate activation is necessary for storing
the status messages. Power OFF clears the ring memory.
Basic representation of the status messages
n: Type / No. / 1
Meaning:
n
:
memory position in the ring memory
Type:
type of message:
I
= info,
W
= warning,
E
= error,
F
= severe system error
No:
internal error detection
1:
frequency of the event (always "1", since no summation occurs)
The status messages within the ring memory are selected with the up/down buttons
.
The enter button
can be used to call up
detailed information
on the corresponding status
messages with the following details:
Service
Status messages
Diagnostics
Expanded diagnostics
ESC
Status messages
1: - / - / -
2: - / - / -
3: - / - / -