background image

About this document

Leuze electronic GmbH + Co. KG

MSI-SR4B

4

1

About this document

1.1

Used symbols and signal words

Table 1.1:

Warning symbols and signal words

Table 1.2:

Other symbols

Table 1.3:

Terms and abbreviations

1.2

Checklists

The checklists (see chapter 9 "Testing") serve as a reference for the machine manufacturer or supplier. 

They replace neither testing of the complete machine or system prior to the initial start-up nor their periodic 

testing by a competent person. The checklists contain minimum testing requirements. Depending on the 

application, other tests may be necessary.

Symbol indicating dangers to persons

NOTE

Signal word for property damage

Indicates dangers that may result in property damage if the measures for danger 

avoidance are not followed.

CAUTION

Signal word for minor injuries

Indicates dangers that may result in minor injury if the measures for danger avoid

-

ance are not followed.

WARNING

Signal word for serious injury

Indicates dangers that may result in severe or fatal injury if the measures for danger 

avoidance are not followed.

DANGER

Signal word for life-threatening danger

Indicates dangers with which serious or fatal injury is imminent if the measures for 

danger avoidance are not followed.

Symbol for tips

Text passages with this symbol provide you with further information.

Symbol for action steps

Text passages with this symbol instruct you to perform actions.

AOPD

Active Optoelectronic Protective Device

Active Opto-electronic Protective Device

EDM

External Device Monitoring

OSSD

Output Signal Switching Device

SSD

Secondary Switching Device

RES

Start/REStart interlock

PFH

D

Probability of a dangerous failure per hour

Probability of dangerous Failure per Hour

MTTF

d

Mean time to dangerous failure

(Mean Time To dangerous Failure)

PL

Performance Level

Содержание 547950

Страница 1: ...MSI SR4B Safety Relays Original operating instructions EN 2022 03 29 50124419 We reserve the right to make technical changes...

Страница 2: ...2022 Leuze electronic GmbH Co KG In der Braike 1 D 73277 Owen Germany Phone 49 7021 573 0 Fax 49 7021 573 199 http www leuze com info leuze de...

Страница 3: ...ection 13 7 1 Terminal assignments 13 7 2 Circuit diagram examples 14 8 Starting up the device 16 8 1 Switching on 16 8 2 Start restart 16 8 2 1 Unlocking start restart interlock 16 9 Testing 17 9 1 B...

Страница 4: ...njuries Indicates dangers that may result in minor injury if the measures for danger avoid ance are not followed WARNING Signal word for serious injury Indicates dangers that may result in severe or f...

Страница 5: ...quipment directive 2009 104 EC OSHA 1910 Subpart 0 Safety regulations Accident prevention regulations and safety rules Ordinance on Industrial Safety and Health and employment protection act Product s...

Страница 6: ...angerous movement The construction of the safety relay must not be altered When manipulating the safety relay the pro tective function is no longer guaranteed Manipulating the safety relay also voids...

Страница 7: ...safety at work Regular testing by competent persons 2 4 Exemption of liability Leuze electronic GmbH Co KG is not liable in the following cases Safety relay is not used as intended Safety notices are...

Страница 8: ...ed for installation on the DIN rail in the cabinet and is wired via the 16 terminals All connection terminals are pluggable The individual terminal blocks are mechanically coded to prevent swapping or...

Страница 9: ...tact as auxiliary power circuit LED displays Power K1 and K2 Reset Operating voltage 24 V AC DC Housing width 22 5 mm Removable connection terminal blocks screw terminals spring cage terminals 3 2 Dis...

Страница 10: ...ective sensor Two channel sliding safety guard monitoring see figure 7 3 Based on the specified signal sequence when using two forced position switches the direction depen dent actuation of the contac...

Страница 11: ...t recognition up to category 4 EN ISO 13849 1 2015 Single channel protective door monitoring up to category 2 EN ISO 13849 1 2015 Two channel protective door monitoring up to category 4 EN ISO 13849 1...

Страница 12: ...ective device acc to EN ISO 13855 1 2010 and IEC 61496 2 2020 Snap the safety relay onto the DIN rail The safety relay can be connected to the safety sensors WARNING Improper mounting may result in se...

Страница 13: ...r the various functions are connected DANGER Risk of death by electric shock Depending on external wiring dangerous voltages may be present at the switching outputs During all work at the electrical s...

Страница 14: ...upply contacts 24V OUT S22 Sensor input S12 Sensor input A2 0V S34 Restart automatic output S31 Sensor input 14 Relay contact 1 OUT 24 Relay contact 2 OUT 34 Relay contact 3 OUT 42 Signal contact IN M...

Страница 15: ...nd manual start n c FP 4 FP 3 FP 2 Alarm n c Restart 24V ROTOSCAN RS4 4 FP 1 n c n c OSSD2 OSSD1 X1 X2 reserved n c n c RS232 422 RxD RxD TxD TxD 8 1 15 9 1 5 6 9 13 6 7 8 A1 X2 1 X1 2 X1 1 3 12 11 10...

Страница 16: ...al operation of the system following process interruptions triggering of the protective function failure of the voltage supply see chapter 8 2 1 Unlocking start restart interlock 8 2 1 Unlocking start...

Страница 17: ...eir respective tasks The training is the responsibility of the operating company Check whether the safety relay was correctly selected acc to the locally applicable regulations and directives Check wh...

Страница 18: ...n remeasured and recorded in the machine documents Is the required safety distance protective field to the next point of operation main tained Are all points of operation of the machine accessible onl...

Страница 19: ...Tester authorized operating personnel or instructed person Table 9 2 Check list daily or at change of shift WARNING Unpredictable machine behavior during the test may result in serious injury Make ce...

Страница 20: ...Maintenance Leuze electronic GmbH Co KG MSI SR4B 20 10 Maintenance The safety relay is maintenance free...

Страница 21: ...Disposing Leuze electronic GmbH Co KG MSI SR4B 21 11 Disposing For disposal observe the applicable national regulations regarding electronic components...

Страница 22: ...together with a description Please register the merchandise concerned Simply register return of the merchandise on our website www leuze com under Contact Support Repair Service Returns To ensure quic...

Страница 23: ...ge UB 24 V AC DC s20 Power consumption 3 W External safeguarding for supply circuit 200 mA delay action Output contacts 3 NO contacts 1 NC contact Ag alloy Switching capacity of the contacts acc to EN...

Страница 24: ...pply network is provided by means of a separate transformer from medium voltage Class B Commercial industrial locations and residential areas that are supplied by the public 230V network low voltage n...

Страница 25: ...Technical data Leuze electronic GmbH Co KG MSI SR4B 25 Figure 13 2 Dimensions MSI SR4B 02 22 5 111 114 1 111 5...

Страница 26: ...ze electronic GmbH Co KG MSI SR4B 26 14 Order guide Table 14 1 MSI SR4B safety relays Part no Article Description 547950 MSI SR4B 01 Safety relay screw terminals 547951 MSI SR4B 02 Safety relay spring...

Отзывы: