Optical data

Operating range

0.7 … 5 m

Maximum number of beams

64 (as special variant: up to 96)

Light source

LED (modulated light)

Wavelength

880nm

Permissible angular deviation

±10° (between the transmitter bar and receiver bar)

Timing

Cycle time

parallel beam analysis:

1 ms per beam but min. 30 ms

parallel/diagonal beam analysis: 2 ms per beam but min. 60 ms

Electrical data

Operating voltage U

B

 

1)

1)

2=polarity reversal protection, use a grounded voltage supply!

24V DC (+20%; -15%)

Power consumption

Approx. 8W

Outputs 

2)

2)

2=polarity reversal protection, 3=short-circuit protection for all transistor outputs

semiconductor output

/4

: PNP

/2

: NPN

Output current

max. 200 mA

Indicators

Control LEDs

2 x status LEDs in receiver bar, 
1 x status LED in transmitter bar

Mechanical data

Light curtain housing

aluminium, natural anodising, front cover made of plastic, dark 
red. (do not use any cleaning agents containing solvents!)

Profile cross section

12 x 58mm with 5mm beam spacing, 
10 x 27mm with other beam spacings

Connection

receiver: 4-pin, transmitter 3-pin

,4000

:

cable variants, 
round cables with PVC sheathing Ø 4.9mm, length 4m, 
with ferruled ends, core cross section 0.37mm

2

-S8

:

M8 connector, 4-pin

Environmental data

Operating temperature

-10°C … 45°C

Humidity

up to 90 % relative, non-condensing

Interference rejection – ambient 
light

operation with no interference with the effect caused by a halogen 
light source, 500W, outside the ±15° angular range of the beam 
axis, distance of 1m.
operation with no interference with sunshine up to 200,000LUX 
outside the ±25° angular range of the beam axis.

Protection class 

IP54

Standards applied

EN 60947-5-2,
EN 61000-6-3/4, 
EN 61000-6-1/2, 
EN 61000-4-2

Options

Automatic calibration

Содержание VARIO B

Страница 1: ...VARIO B switching light curtain for object detection GB 01 01 09 50107856 T E C H N I C A L D E S C R I P T I O N...

Страница 2: ...t 38 044 4961818 C illies Co Ltd Tel Int 81 3 3443 4143 Fax Int 81 3 3443 4118 Profa Tech Ltd Tel Int 254 20 828095 6 Fax Int 254 20 828129 Leuze electronic Co Ltd Tel Int 82 31 3828228 Fax Int 82 31...

Страница 3: ...eral information 6 3 2 Performance features 6 3 3 Function 7 3 4 Configuration interface 8 3 5 Configuration software 9 3 6 Parameters 10 4 Mounting and commissioning 13 4 1 Electrical connection 14 4...

Страница 4: ...VARIO B light curtain 14 Figure 4 3 Pin assignments of the cable of the VARIO B light curtain 14 Table 4 1 Flashing codes of the receiver LEDs during the calibration sequence 15 Table 4 2 Display of r...

Страница 5: ...ation may lead to in juries to personnel or damage to the equipment Notice This symbol indicates text passages containing important information 1 3 Declaration of Conformity The VARIO B switching ligh...

Страница 6: ...for medical purposes Attention The light curtains are not certified safety light barrier in accordance with EN 61496 They are not safety components in the spirit of EC machine directive 89 392 EEC wit...

Страница 7: ...e electronic VARIO B 5 TNT 35 7 24V Qualified personnel Mounting commissioning and maintenance of the device must only be carried out by qualified personnel Electrical work must be carried out by a ce...

Страница 8: ...circuit proof light or dark switching Reliable and flexible operation Warning output PNP or NPN short circuit proof for conditions including soil ing malfunction and normal functionality Ensures avai...

Страница 9: ...4000 The products can be installed acc to Plug and Play as follows Install light strips Perform automatic calibration cycle see chapter 4 4 System is now ready The light strips are synchronised via an...

Страница 10: ...e www leuze com under Measuring and switching light curtains Figure 3 1 VB Int 232 interface module Connection Connect the VB Int 232 interface module Part No 501 07711 according to the label to a 24V...

Страница 11: ...tton The connected receiver bar can be activated and deactivated using the Power X button In general parameters are changed in the white fields Changed values are indicated by italic text with a yello...

Страница 12: ...n a manner analogous to that for the receiver bar Max defect tolerance Definition of the maximum tolerable noisy or defective receive signals before the system switches to fault mode flashing LEDs Att...

Страница 13: ...o 255 Default 0 Start 2nd detection range Definition of a second switching range beginning with beam x 0 Complete measurement field length is detection range warning function is 2nd output 2 Warning o...

Страница 14: ...ield is interrupted at least 1 beam Switching behaviour corresponding to the PNP or NPN signal definitions Attention Mode Dark switching corresponds to the inverse of the light switching signal Input...

Страница 15: ...ong time they may penetrate the bar and damage the electronics Increased risk of soiling 4 Protect the cable from being crushed and from exposure to strong electromagnetic effects 5 Strong extraneous...

Страница 16: ...e exceeded 4 Insulate unused wires 4 1 1 M8 plug version Figure 4 2 Pin assignment of the M8 connector of the VARIO B light curtain 4 1 2 Cable version Round cable length 4m 4 9mm Figure 4 3 Pin assig...

Страница 17: ...at the same rate Excessive value differences of the individual beams or beams have not yet been calibrated Check the alignment of the light curtain strips Flashing Flashes alternately Self test detec...

Страница 18: ...eceiver flashes once indicating that data are being saved 7 Check the functionality of the light curtain in the entire monitoring area using an opaque object The calibration items 3 to 6 yellow wire i...

Страница 19: ...transmitter LED flashes LED1 1 LED2 active switching output active Low active de activation signal 0V Relative threshold output 0 Relative threshold warn 3 all beams switched off transmitter LED flas...

Страница 20: ...x status LED in transmitter bar Mechanical data Light curtain housing aluminium natural anodising front cover made of plastic dark red do not use any cleaning agents containing solvents Profile cross...

Страница 21: ...nt field length in mm see table 6 1 on page 20 Electrical connection S8 M8 connector 4000 cable length in mm IVBR 4 2 1 5 7 0 8 8 0 4 0 0 0 Type IVBR VARIO B receiver Beam spacing in mm 5 12 5 25 50 1...

Страница 22: ...on page 20 Measurement function 00 light switching parallel beam analysis 01 light switching parallel and diagonal beam analysis 02 dark switching parallel beam analysis 03 dark switching parallel and...

Страница 23: ...388 32 560 80 500 10 27 13 5 158 5 VB 12 5 488 12 5 488 40 660 80 600 10 27 13 5 158 5 VB 12 5 588 12 5 588 48 760 30 700 10 27 13 5 158 5 VB 12 5 688 12 5 688 56 860 80 800 10 27 13 5 158 5 VB 12 5 7...

Страница 24: ...160 80 500 10 27 20 190 VB 50 2350 50 2350 48 2560 80 600 10 27 20 190 VB 50 2750 50 2750 56 2960 80 700 10 27 20 190 VB 50 3150 50 3150 64 3360 80 800 10 27 20 190 VB 100 700 100 700 8 970 85 400 10...

Отзывы: