Product description
10
VARIO B
Leuze electronic
3.6
Parameters
Synchronisation beam
Specifies the position of the optical synchronisation beam.
Attention!
If the synchronisation beam is interrupted, both switching outputs are activated
automatically!
Input option:
first beam
last beam
Default:
first beam (connector/cable end)
Attention!
If the synchronisation setting is changed, this parameter must also be changed on the trans-
mitter bar! To do this, connect the black pin (pin 4 on the connector) to terminal KL6 of the
VB-Int-232 interface module; the configuration routine is performed in a manner analogous
to that for the receiver bar.
Max defect tolerance
Definition of the maximum tolerable noisy or defective receive signals before the system
switches to fault mode (flashing LEDs).
Attention!
A signal is also marked as defective if it is interrupted for longer than the
set "warning time"!
Input option:
0 to 255
Default: 4
Relative threshold warn
Definition of the signal threshold as a %; if, while in the "non-interruption state", the value
falls below the value set here, soiling is indicated. The setting is made numerically in the
range from 0 … 255, whereby value ’255’ corresponds to 100% of the calibration threshold.
Input option:
0 to 255 (0 … 100%)
Default: 147
(58%)
Warn signal delay [s]
Definition of the response time in s for the warning function.
Input option:
0 to 255
Default: 60