Troubleshooting
Leuze electronic
SOLID-4
53
T
N
T
35/
7-
24V
DEUTSCH
ENGLISH
FRANÇAIS
IT
ALIANO
ESPAÑO
L
NEDERLANDS
Table 10.2-2:
Receiver diagnostics
F9
OSSD short circuit after VCC or cross
circuit, output 2
Remove short circuit after VCC or cross
circuit; if it occurs again, send the device
in
F10
Undervoltage on power supply
Check power supply and feed
F20
Internal hardware fault
Send the device in
F21
Internal hardware fault
Send the device in
F22
Internal hardware fault
Send the device in
F23
Internal hardware fault
Send the device in
F24
Internal hardware fault
Send the device in
F25*
Different transmission channels discov-
ered (during operation)
Switch supply voltage off and on again
F26*
Different evaluation procedures (SCAN)
discovered (during operation)
Switch supply voltage off and on again
F27
Internal hardware fault
Send the device in
F28
Internal hardware fault
Send the device in
F29
Internal hardware fault
Send the device in
F30
Error in semiconductor test (timeout or
multifuse)
Turn supply voltage off and on again; if it
occurs again, send the device in
F32*
RES operating mode changed
(during operation)
Switch supply voltage off and on again
F33*
EDM operating mode changed
(during operation)
Switch supply voltage off and on again
F34*
EDM timeout exceeded (feedback circuit
closes or will not open)
Check EDM wiring, turn supply voltage
off and on again
F35*
Start/restart button pressed longer than
10 seconds
Check the start button wiring
F36
Test identification signal from transmitter
longer than 3 seconds
Check transmitter test input
F37*
EDM configuration error
Check EDM wiring, turn supply voltage
off and on again
F38
Internal hardware fault
Send the device in
Code Cause/significance
Activity for removing errors
*)
Locking error - a system reset is only achieved by switching the supply voltage off and on.