5.3
Mechanical mounting
What should generally be taken into consideration during installation?
✟
Make certain that the transmitter and receiver are mounted on even surfaces.
✟
The transmitter and receiver must be positioned at the same height and their
connection plugs must be pointing in the same direction.
✟
Use screws for mounting that can only be loosened with a tool.
✟
Fasten and secure the transmitter and receiver so that they cannot be swiveled or
moved. Securing transmitter and receiver so they cannot be moved or swiveled is
especially important in the close area with a narrow protective field.
✟
The safety distance between the protective field and the danger zone must be
observed.
✟
Make certain that access to the danger point/danger area is only possible through the
protective field. Additional access routes must be secured separately (for example by
hard guards, additional safety light curtains or doors with locking devices).
5.4
Mounting types
5.4.1
Standard mounting
Four standard mounting brackets (two each for transmitter and receiver) are included with
delivery.
Fig. 5.4-1:
Standard mounting bracket examples