Electrical connection
Leuze electronic
rotoScan ROD4...
21
TNT 35/7-24V
5.1.2
Connector assignments for connection Y1
Table 5.2:
Pin assignments for connection Y1
Notice!
For interfaces Y1 to Y4, ready-made cables are also available. See "Accessories" on
page 37.
5.1.3
Connector assignments for connection Y2 (Ethernet)
Table 5.3:
Pin assignments for connection Y2
For an Ethernet connection, you should connect TX+ to TX+, TX- to TX-, RX+ to RX+ and
RX- to RX-. The contact assignments on the Y2 M12-socket correspond to the PROFInet
PIN
Signal
Description
A
U
B
Supply v24VDC
C
GND
Supply voltage ground
E
FPS1
Switch to detection field pair 1
G
FPS2
Switch to detection field pair 2
J
FPS3
Switch to detection field pair 3
L
FPS4
Switch to detection field pair 4
M
Restart
Safe input "restart-disable", reset the ROD4…plus
and connection of the restart button
N
Fn1
Semiconductor output, shutdown on object detection
in the
near
detection field, channel 1.
O
Fn2
Semiconductor output, shutdown on object detection
in the
near
detection field, channel 2.
P
ALARM2 Warning and error output.
R
ALARM1
Output for object detection in the
far
detection field
and for warning messages such as "Window lightly
soiled" or "Window heavily soiled" (configurable).
S
NC
Do not use!
T
NC
Do not use!
U
NC
Do not use!
PIN
Signal
Description
1
TX+
Data communication, transmission
3
TX-
Data communication, transmission
2
RX+
Data communication, reception
4
RX-
Data communication, reception