RFM-Setup tipps

 

Leuze 

electronic

 

Page 3 of 3 

Leuze 

electronic

 

RFM 12/ RFM 32/ RFM 62 on Ethernet via MA 208i 
 
After mounting of the RFM and the MA, and setting the IP address(SW) at the 
SPS. The configuration of the  RFM is done very easy via service interface of 
the MA208i and the RF-config tool. To do so please set all DIP–switches to 
„Service“and“DEV“. When the configuration is finished set back the DIP-
switches to„RUN”.  
The complete configuration telegram could be send directly from the PLC to 
the RFM (like a Command telegram). The structure and the description of the 
parameters are in the “telegram and command structure” file. 
If communicating to the RFM device via Ethernet please note that each 
character is handled as ASCII-character and must be transfered into 
hexadecimal. With very long commands or telegrams, each part of the telegram 
has to be stored in the memory of the MA 208i in the collecting mode (look for 
correct sequence). If the telegram/ command is complete in the memory of the  
MA 208i, transfer the whole content with the bit „SFB“ to the RFM.  
For more details concerning the MA 208i please see the technical manual  
 
 
 
RFM 12/ RFM 32/ RFM 62 on PROFINET via MA 248i 
 
After mounting of the RFM and the MA, by the integration of the GSDML-file 
into the PROFINET master, all configuration data of the MA 248i is usable for 
the PLC. The configuration of the RFM is done very easy via service interface 
of the MA248i and the RF-config tool. To do so please set DIP–switches to 
„Service“and“DEV“. When the configuration is finished set back the DIP-
switches to„RUN“ operation). If communicating to the RFM device 
via PROFINET please note that each character is handled as ASCII-character 
and must be transfered into hexadecimal .  
The complete configuration telegram could be send directly from the PLC to 
the RFM (like a Command telegram). The structure and the description of the 
parameters are in the “telegram and command structure” file. 
If communicating to the RFM device via ProfiNet please note that each 
character is handled as ASCII-character and must be transfered into 
hexadecimal. With very long commands or telegrams, each part of the telegram 
has to be stored in the memory of the MA 248i in the collecting mode (look for 
correct sequence). If the telegram/ command is complete in the memory of the  
MA 248i, transfer the whole content with the bit „SFB“ to the RFM.  
For more details concerning the MA 248i please see the technical manual  
 
 