Configuration / Parameter Setting
#Leuze
#Leuze electronic
GmbH + Co KG, Postfach 11 11, D-73277 Owen/Teck, In der Braike1, D-73277 Owen/Teck, Tel. ++49 (0)7021/5730, Fax ++49 (0)7021/573199
Page 22 of 28
LZ - ELE - BA - GB - 0006 - 06
Date: 01.12.2004
corresponding parameter data:
Error value
Determines, which data value should be transmitted in the module position in the case
of an error. The data value is output, if the laser can output no more measurement.
This is given e.g., if a beam interruption is present.
The available options are:
Null (default)
The position is set to "0"
0xFF
All 24 bits are set to '1' (0xFFFFFF or -1)
last valid value
Output of the last valid position
4.1.4 Module Acceleration
Is not supported at the moment!
4.1.5 Module Counter Measuring-Cycle
The module uses two input words which are consistently transferred via the bus.
Over the input words the counter reading of the measuring-cycle counter is
transferred. Every correct measuring cycle in the device increases the counter reading
by 1. An overflow of the 32-bit counter causes a new beginning with "0".
Input double word ID x
LSB
MSB
Input byte x+0
Input byte x+1
input byte x+2
Input byte x+3