![Leuze electronic MLC 520 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/leuze-electronic/mlc-520/mlc-520_original-operating-instructions_1884027035.webp)
Electrical connection
Leuze electronic
MLC 520 EX
35
Table 7.2:
Pin assignment receiver
The polarity of the supply voltage selects the transmission channel of the receiver:
• VIN1 = +24 V, VIN2 = 0 V: transmission channel C1
• VIN1 = 0 V, VIN2 = +24 V: transmission channel C2
Pin
Core color (CB-M12-xx000E-5GF)
Receiver
1
White
IO1 - control input reset button, signal output
Start/restart normal open contact against
ground 24 V DC weak signal/fault:
24 V DC strong light reception
0 V weak light reception or fault
2
Brown
VIN1 - supply voltage
24 V DC for transmission channel C1
0 V for transmission channel C2
3
Green
IN3 - control-input contactor monitoring (EDM)
24 V DC: without EDM
0 V: with EDM and feedback circuit closed
High-impedance: with EDM and feedback cir
-
cuit open
4
Yellow
IN4 - control input for start/restart interlock
(RES)
24 V DC: with RES
Bridge to pin 1: without RES (notice: signal out
-
put remains functional)
5
Gray
OSSD1 - safety-related switching output
6
Pink
OSSD2 - safety-related switching output
7
Blue
VIN2 - supply voltage
0 V: for transmission channel C1
24 V DC for transmission channel C2
8
Red
FE - functional earth, shield
Wired in device interior on the housing
FE
FE - functional earth, shield