![Leuze electronic MLC 520 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/leuze-electronic/mlc-520/mlc-520_original-operating-instructions_1884027022.webp)
Mounting
Leuze electronic
MLC 520 EX
22
1
Safety sensor
2
Danger zone
3
Floor
a
Height of the point of operation
b
Height of the upper beam of the safety sensor
Figure 6.1: Additional distance to the safety distance when reaching over and under
Table 6.1:
Reaching over the vertical protective field of electro-sensitive protective
equipment(excerpt from EN ISO 13855)
a
3
C
RO
KxT
b
1
2
S
RO
Height a of
the point of
operation
[mm]
Height b of the upper edge of the protective field of the electro-sensitive protective equip
-
ment
900
1000 1100 1200 1300 1400 1600 1800 2000 2200 2400 2600
Additional distance C
RO
to the danger zone [mm]
2600
0
0
0
0
0
0
0
0
0
0
0
0
2500
400
400
350
300
300
300
300
300
250
150
100
0
2400
550
550
550
500
450
450
400
400
300
250
100
0
2200
800
750
750
700
650
650
600
550
400
250
0
0
2000
950
950
850
850
800
750
700
550
400
0
0
0
1800
1100 1100 950
950
850
800
750
550
0
0
0
0
1600
1150 1150 1100 1000 900
850
750
450
0
0
0
0
1400
1200 1200 1100 1000 900
850
650
0
0
0
0
0
1200
1200 1200 1100 1000 850
800
0
0
0
0
0
0
1000
1200 1150 1050 950
750
700
0
0
0
0
0
0
800
1150 1050 950
800
500
450
0
0
0
0
0
0
600
1050 950
750
550
0
0
0
0
0
0
0
0
400
900
700
0
0
0
0
0
0
0
0
0
0
200
600
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0