Technical data
Leuze electronic
MLC 510 AS-i Host/Guest
48
A
5
3
L = 340
H
R
R
B
C
PFN
H
PFE
Fig. 14.3:
Dimensions of Guest transmitter and Guest receiver
Effective protective field height H
PFE
goes beyond the dimensions of the optics area to the outer borders of
the circles labeled with R.
Calculation of the effective protective field height
H
PFE
[mm]
=
Effective protective field height
H
PFN
[mm]
=
Nominal protective field height (length of the yellow housing part) (see tables below)
A
[mm]
=
Total height
B
[mm]
=
Additional dimensions for calculation of the effective protective field height (see table below)
C
[mm]
=
Value for calculating the effective protective field height (see tables below)
Tab. 14.7:
Additional dimensions for calculating the effective protective field height
R = resolution
B
C
14 mm
6 mm
6 mm
20 mm
7 mm
10 mm
30 mm
19 mm
9 mm
40 mm
25 mm
15 mm
90 mm
50 mm
40 mm
Tab. 14.8:
Dimensions (nominal protective field height), weight and response time for Host devices
Device type
Host transmitter and Host receiver
Host receiver
Dimensions [mm]
Weight [kg]
Response time [ms] acc. to resolution
Type
H
PFN
A
14 mm
20 mm
30 mm
40 mm
90 mm
MLC…-300
300
366
0.53
8
7
4
4
-
MLC…-450
450
516
0.68
11
9
5
5
3
MLC…-600
600
666
0.83
14
12
7
7
3
MLC…-750
750
816
0.98
17
14
8
8
4