Device description
Leuze electronic
MLC 510 AS-i Host/Guest
15
3.4.2
Operating indicators on the MLC 510/A receiver
Located on the receiver are two LEDs for displaying the operating state:
1
3
4
2
1
LED1, red/green
2
LED2, red/yellow/green
3
State/error
4
AS-i
Fig. 3.6:
Indicators on the MLC 510/A receiver
Tab. 3.3:
Meaning of the LEDs on the receiver
LED
Color
State
Description
1
Red/green
OFF
Device switched off
Red
Protective field interrupted
Red, slowly flashing (approx. 1 Hz)
External error
Red, flashing fast (approx. 10 Hz)
Internal error
Green slowly flashing (approx. 1 Hz) Protective field free, weak signal
Green
Protective field free
2
Red/yellow/green Red
AS-i slave not communicating with
AS-i master
ON
OSSD off, transmission channel
C2
Green
AS-i slave communicating with
AS-i master
Yellow flashing
AS-i slave has invalid address 0
Red, flashing
AS-i slave device error or AS-i
connection defective
Red/green, flashing alternately
Periphery error
OFF
No voltage