Specifications
Leuze electronic
Technical description LES
129
TNT
35/7-2
4
V
PROFIBUS (only LES 36/PB)
Interface type
1x RS 485 on X4
Protocols
PROFIBUS DP/DPV1 slave
Baud rate
9.6kBaud … 6MBaud
Indicators
Green LED
continuous light
ready
off
no voltage
Yellow LED
continuous light
Ethernet connection available
flashing
Ethernet data transmission active
off
no Ethernet connection available
Mechanical data
Housing
aluminum frame with plastic cover
Optics cover
glass
Weight 620g
Connection type
M12 connector
Environmental data
Ambient temp.
(operation/storage)
-30°C … +50°C/-30°C … +70°C
Protective circuit
9)
1, 2, 3
VDE safety class
III, protective extra-low
voltage
Protection class
IP 67
Laser class
2M (according to EN 60825-1 and
21 CFR 1040.10 with Laser Notice No. 50)
Standards applied
IEC/EN 60947-5-2, UL 508
1)
Luminosity coefficient 6% ... 90%, entire measurement range, at 20°C after 30minutes
warmup time, medium range U
B
2)
Minimum and maximum value dependent on the measurement distance, at 20°C after
30min. warmup time, average range U
B
,
z
-resolution at factory setting median "3"
3)
Reflectivity 90%, identical object, identical environment conditions, measurement object
20x20mm²
4)
Minimum value, depends on distance and object, requires testing under application
conditions
5)
For UL applications: for use in class 2 circuits according to NEC only
6)
The push-pull switching outputs must not be connected in parallel
7)
Number of detection fields: up to 16 with logic operation option
8)
Number of inspection tasks: up to 16 (8 of these can be activated via inputs)
9)
1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all
outputs, requires external protective circuit for inductive loads