Leuze electronic LCAM 408i Скачать руководство пользователя страница 12

 

12 

3.6.2  RTSP-Protocol 

(Softwareversion 45d1eab)

 

The LCAM supports the livestream on the RTSP-Protocol. 

You can use the with e.g. Siemens Comfort-Panel 

rtsp://192.168.60.101:554/jpeg 

(It shows the Default IP-Adrdess of the LCAM) 

Important:

 The RTSP-Protocol allow maximum Pixels up to 2000. Therefore we recommend to use 

as maximum the picture resolution of 1920x1080 pixel (FullHD) 

 

 

3.6.3  Live stream in the browser 

(Softwareversion 45d1eab)

 

The LCAM supports the livestream in the browser. 

You can use the with e.g. Mozilla Firefox 

http://192.168.60.101/camera/live_image.lp  

(It shows the Default IP-Adrdess of the LCAM) 

Remark:

The Camera-resolution can be choose from 640x480 to 2592x1944 pixel  

 

 

 

 

Содержание LCAM 408i

Страница 1: ...LCAM 408i Industrial Ethernet Camera User Manual Revision 1 2...

Страница 2: ...s This device may not cause harmful interference and This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and foun...

Страница 3: ...local power company If the power supply is broken do not try to fix it by yourself Contact a qualified service technician or your retailer Operation safety Before installing the motherboard and addin...

Страница 4: ...face 8 3 1 Changing Camera IPs 8 3 2 Default network settings 9 3 3 Default login data 9 Web interface 9 SSH 9 3 4 Camera Settings 10 3 5 Still image 10 3 6 Streaming 11 3 6 1 Stream data structure 11...

Страница 5: ...H 1 1 M12 connectors The M12 connectors on the bottom side are used for Ethernet connection named with SERVICE and the other for Power Supply named with PWR It is an X coded M12 with 8 pins female and...

Страница 6: ...system is used to store persistent data 1 5 Optics The lens M12 is mounted behind a protective front glass no optical requirements that cannot be changed be the user The setup the lens focus is done i...

Страница 7: ...7 1 6 2 At a Rod 14 20mm with the BT 56 1 or BT 300 1 1 6 3 With a mounting angle The camera can mount to the BT 300W and adjust in different directions...

Страница 8: ...fixed address see below You may have to change the PC s IP to an address like 192 168 60 101 so it is in the same sub net Open Internet browser on the computer In the browser s address line type in th...

Страница 9: ...101 This is in one of the private IP spaces IP Mask 255 255 0 0 Gateway Not needed for test change for large nets DNS server Not needed for test change for large nets Order number xxx Camera individu...

Страница 10: ...effect Sleep between snaps only used in webcam mode not in streaming mode Automatic gain correction enables the automatic exposure control Flicker free exposure if 0 no flicker free exposure is used...

Страница 11: ...aching and IP address if not done so on the command line 3 6 1 Stream data structure To access the video data in your own software open a socket to port 5001 of the camera and scan the incoming data f...

Страница 12: ...P Protocol allow maximum Pixels up to 2000 Therefore we recommend to use as maximum the picture resolution of 1920x1080 pixel FullHD 3 6 3 Live stream in the browser Softwareversion 45d1eab The LCAM s...

Страница 13: ...The LCAM 408i has an internal web server that has the following menus 4 1 Administration 4 1 1 Factory reset 4 1 2 Password selection Here one of the two possible passwords can be selected to be chan...

Страница 14: ...14 4 1 3 Password setting Here passwords are changed and set 4 1 4 Reboot System reboot is done without further data and should be finished after a minute...

Страница 15: ...eams with the same content on different ports one full size and one scaled down When the image size is set to values smaller than half the linear sensor pixel number see data sheet below binning is en...

Страница 16: ...anging the exposure time For values 0 exposure time is limited to multiples of the value Exposure values in between are realized by changing the gain For 50Hz lighting flicker free exposure is realize...

Страница 17: ...eters can be set At the moment camera settings can only be changed by the web interface It is possible to change the exposure time the gain of the different color channels image flipping and Bayer mod...

Страница 18: ...mounting position of the camera Changes Bayer mode which is fixed yet See below Bayer mode because the flipping will change the starting pixels the Bayer mode the mode has to be adjusted if flipping...

Страница 19: ...d DHCP mode For static IP fill out the fields as needed And press Save data To use the new settings pressing Restart network is needed For DHCP mode no addresses are needed they are obtained from the...

Страница 20: ...20 4 4 Menu general appearance This image shows the general menu structure 4 5 About Menu The About screen shows data needed for service enquiries or for searching a camera in the network...

Страница 21: ...21 5 Appendix Data sheet key data Below you find the key data for the sensor...

Отзывы: