background image

IT 4820 - 03

0705

Leuze 

electronic

Trigger

To activate the read process, a trigger signal is to be sent via the serial RS 232 interface or USB interface (COM port emulation 
only). The command is to be sent at the set baud rate, parity, and data and stop bits. 

The command for activation is: 

SYN T CR

 

ASCII decimal values: 022; 084; 013

To cancel read readiness, send a deactivation. 

The command for deactivation is: 

SYN U CR

ASCII decimal values: 022; 085; 013

Following a successful read operation, the IT 4820 deactivates itself.

The second option is activation via the built-in trigger button.

Configuration for the Leuze standard protocol

Scan the adjacent 2D code. 
The IT 4820 is set to the following transmission parameters: 
RS 232 transmission with 9,600 baud, 8 data bits, 1 stop bit, no parity, prefix <STX>, 
terminators <CR><LF>.

IT 4820

Содержание IT 4820

Страница 1: ...ies z TTL RS 232 cable PIN 9 IT 4xxx Part No 501 04586 z PS 2 cable for IT 4xxx Part No 501 03409 z USB cable for IT 4xxx Part No 501 03404 z Power supply unit for IT 4x2x Part No 501 03989 Dimensione...

Страница 2: ...0 C Relative air humidity 0 95 non condensing 0 95 non condensing Protection class IP 41 IP 41 IT 4820 SR Module or cell from to Bar codes 8 3mil 0 21mm 89mm 191mm UPC bar code 13mil 0 33mm 53mm 333mm...

Страница 3: ...red illumination should now be visible Now scan a sample label The scanner emits an audible signal to confirm that the label has been read if necessary the data are now passed on to the computer Conf...

Страница 4: ...lues 022 084 013 To cancel read readiness send a deactivation The command for deactivation is SYN U CR ASCII decimal values 022 085 013 Following a successful read operation the IT 4820 deactivates it...

Страница 5: ...e other end into a free power socket 5 4 Switch the PC back on 5 Scan the adjacent barcode The IT 4820 is set to the following transmission parameters RS 232 transmission with 115 200 baud 8 data bits...

Страница 6: ...2 white TXD 1 blue GND 4 red VCC black GND bare shield PE 21 Procedure 1 Connect cable KB 021 Z to the MA 41 acc to the above pin assignments 2 Connect the interface cable to cable KB 021 Z Connect t...

Страница 7: ...black GND bare shield PE 21 Procedure 1 Connect cable KB 021 Z to the MA 21 acc to the above pin assignments 2 Connect the interface cable to cable KB 021 Z Connect the interface cable and the power...

Страница 8: ...4820 XX 0C1C 1x 501 03 990 Base station ST 2020 1x 501 03 989 Power supply unit ST 2020 1x 501 03 409 PS 2 cable Procedure 1 Switch off the PC 2 Disconnect the keyboard 3 Connect the cable for the ST...

Страница 9: ...currently activated program Thus the data can be processed further in all standard programs required parts 1x IT 4820 XX 0C1C 1x 501 03 990 Base station ST 2020 1x 501 03 989 Power supply unit ST 2020...

Страница 10: ...equired parts 1x IT 4820 XX 0C1C 1x 501 03 990 Base station ST 2020 1x 501 03 989 Power supply unit ST 2020 1x 501 03 404 USB cable Procedure 1 Connect the cable for the ST 2020 base station to a free...

Отзывы: