IT 4820 - 03
0705
Leuze
electronic
Connecting the IT 4820 to the USB interface (COM-port emulation)
The operation of the IT 4820 as a serial interface on a USB port is described in this chapter. A COM interface is emulated in this
operating mode. The data which are read in are sent to a new COM interface. The driver with which you emulate this COM interface
can be downloaded from our homepage at
www.leuze.de. Thus, the data can be processed further in programs which expect data
via COM interfaces.
required parts:
1x
IT 4820 XX 0C1C
1x
501 03 990
Base station ST 2020
1x
501 03 989
Power supply unit ST 2020
1x
501 03 404
USB cable
Procedure:
1.
Connect the cable for the ST 2020 base station to a free
USB port.
2.
The scanner acknowledges this connection with a beep.
3.
Scan the adjacent 2D code.
4.
Install the USB serial driver when you are prompted to do
so by Windows.
5.
Open a terminal program or your program for the serial
interface, select the new COM port, and make the follow-
ing settings: baud rate 38,400, 8 data bits, 1 stop bit, no
parity, terminator <CR>.
Notice!
To charge the IT 4820, the power supply unit
must be plugged in and the hand-held scanner
placed in the ST 2020 base station.
IT 4820