![Leuze electronic IT 1910i Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/leuze-electronic/it-1910i/it-1910i_technical-description_1883933019.webp)
5.6 IT 1910i to USB interface (COM port emulation)
The operation of the IT 1910i as a serial interface on a USB port is described in this chapter. A COM interface
is emulated in this operating mode. The data which are read in are sent to a new COM interface. The driver
with which you emulate this COM interface can be downloaded from our homepage at
. Thus,
the data can be processed further in programs which expect data via COM interfaces.
Required parts:
1x
50122436
IT 1910i ER-3
1x
50114521
KB USB-1 IT190x
or
50114523
KB USB-2 IT190x
Please connect the IT 1910i acc. to the figures shown below.
To do this, proceed as follows:
1. Install the USB serial driver for the 1910i. To do so, copy the driver
from the CD-ROM or from our homepage to the PC. Unpack the
file and start INSTALL.BAT. This requires administrator privileges
on the PC!
2. Plug the IT 1910i hand-held scanner into a free USB port.
3. The scanner acknowledges this connection with an acoustic
signal.
4. Scan the code shown below.
5. Open a terminal program or your program for the serial interface,
select the new COM port, and make the following settings: baud
rate 115200, 8 data bits, 1 stop bit and no parity. A CR is
transmitted as suffix (or terminator).
Leuze electronic
IT1910i
19