![Leuze electronic HTU318-300 M12 Series Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/leuze-electronic/htu318-300-m12-series/htu318-300-m12-series_quick-start-manual_1883852005.webp)
Leuze electronic GmbH + Co. KG
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
[email protected] • www.leuze.com
Adjusting the switching point via the teach input
The switching point of the sensor is set to 300mm or 1200mm on delivery.
By means of a simple teach event, the switching points can be individually taught to an arbitrary distance within the scanning
range with 1-point teach (static) or 2-point window-teach (static). The Leuze
PA1/XTSX-M12
Teach Adapter can be used for this
purpose. The adapter can also be used to easily switch the output function from NO contact to NC contact.
1-point teach (static)
2-point window-teach (static)
1. Place
object at desired switching distance.
1.
First,
place
object at desired switching distance for
switching point 1
.
2.
To adjust output
OUT1
,
connect
the
Teach-IN
input to
U
B
for
2 … 7s
(Leuze Teach Adapter: position "Teach-U
B
").
The current state of output
OUT1
is frozen while the adjustment is made.
2.
To adjust output
OUT1
,
connect
the
Teach-IN
input to
U
B
for
7 … 12s
(Leuze Teach Adapter: position "Teach-U
B
") until the
yellow and green
LEDs flash alternately at 3Hz
.
3.
The
yellow LED flashes at 3Hz
and is then
ON
.
The current object distance has been taught as the new switching point.
3. Release the button
. The sensor remains in teach mode and the LEDs
continue to flash.
4.
Error-free teach:
LED
states and switching behavior according to the dia-
gram shown above.
Faulty teach
(object may be too close or too far away – please note scan-
ning range)
:
green and yellow LEDs flash at 8Hz
until an error-free teach event is
performed.
The output
OUT1
is inactive as long as there is a teaching error.
4.
Then,
place
the object at the desired switching distance for
switching
point 2
.
Note
:
The
minimum distance between the switching points
is as follows:
scanning range of 400mm:
40mm
scanning range of 1200mm:
120mm
5.
To complete the teach event, briefly
connect
the
Teach-IN
input to
U
B
again (Leuze Teach Adapter: position "Teach-U
B
").
The switching window was taught in.
6.
Error-free teach: LED states and switching behavior according to the
diagram shown above.
Faulty teach
(object may be too close or too far away – please note scan-
ning range)
:
green and yellow LEDs flash at 8Hz
until an error-free teach event is
performed.
HTU318
Ultrasonic sensors with 1 switching output