background image

Leuze electronic GmbH + Co. KG

In der Braike 1 D-73277 Owen 

DMU318-400.W…-M12 - 01

DMU318-1600.W…-M12 - 01

Part number code

Order guide

The sensors listed here are preferred types; current information at 

www.leuze.com

.

D M U 3 1 8 - 1 6 0 0 . W 3 / 4 V K - M 1 2

Operating principle

HTU

Ultrasonic sensor, scanning principle, with background suppression

DMU

Ultrasonic sensor, distance measurement

RKU

Ultrasonic sensor, retro-reflective ultrasonic sensor

Series

318

318 series, cylindrical short M18 design

Scanning range in mm

400

50 … 400

1600

150 … 1600

Equipment

W

Design with 90° angled head

3

Teach button on the sensor

Pin assignment of connector pin 4 / black cable wire (OUT1)

4

PNP output, NO contact preset

P

PNP output, NC contact preset

2

NPN output, NO contact preset

N

NPN output, NC contact preset

Pin assignment of connector pin 2 / white cable wire (Analog OUT/OUT2)

4

PNP output, NO contact preset

P

PNP output, NC contact preset

2

NPN output, NO contact preset

N

NPN output, NC contact preset

C

Analog output 4 … 20mA

V

Analog output 0 … 10V

Pin assignment of connector pin 5 / gray cable wire (Sync / MUX)

K

Synchronization/multiplex input

Connection technology

M12

M12 connector, 5-pin

Designation

Part no.

Scanning range / switching output / analog output / teach-in / design

50 … 400mm / PNP / current output 4 … 20mA / teach button / with 90° angled head

DMU318-400.W3/4CK-M12

50136102 

50 … 400mm / PNP / voltage output 0 … 10V / teach button / with 90° angled head

DMU318-400.W3/4VK-M12

50136100 

50 … 400mm / NPN / current output 4 … 20mA / teach button / with 90° angled head

DMU318-400.W3/2CK-M12

50136103 

50 … 400mm / NPN / voltage output 0 … 10V / teach button / with 90° angled head

DMU318-400.W3/2VK-M12

50136101 

150 … 1600mm / PNP / current output 4 … 20mA / teach button / with 90° angled head

DMU318-1600.W3/4CK-M12

50136108 

150 … 1600mm / PNP / voltage output 0 … 10V / teach button / with 90° angled head

DMU318-1600.W3/4VK-M12

50136106 

150 … 1600mm / NPN / current output 4 … 20mA / teach button / with 90° angled head

DMU318-1600.W3/2CK-M12

50136109 

150 … 1600mm / NPN / voltage output 0 … 10V / teach button / with 90° angled head

DMU318-1600.W3/2VK-M12

50136107 

DMU318…W

90° angled ultrasonic sensors with analog and switching output

Содержание DMU318 W Series

Страница 1: ...PN NO NC function reversible NEW Both outputs can easily be taught using a button NEW Stable plastic design NEW Temperature compensated scanning range 50 400mm 150 1600mm 10 30 V DC 4 20mA 0 10V Acces...

Страница 2: ...utton 12s Indicators Yellow LED OUT2 object detected Blue LED Analog OUT object detected Yellow green or blue green LED flashing Teach in teaching error Green LED Object within the scanning range Mech...

Страница 3: ...contact preset C Analog output 4 20mA V Analog output 0 10V Pin assignment of connector pin 5 gray cable wire Sync MUX K Synchronization multiplex input Connection technology M12 M12 connector 5 pin...

Страница 4: ...rmally closed Close Far Far Close Dead zone Sensor OUT1 active Yellow LED ON Green LED OFF OUT1 not active Yellow LED OFF Green LED ON Distance Hysteresis Switching point Scanning range OUT1 not activ...

Страница 5: ...th 2 point window teach as a function of the switching function 1 Place object at desired switching distance 1 First place object at desired switching distance for switching point 1 2 To adjust the ou...

Страница 6: ...output is changed to the opposite state toggled First activate the previously described teach mode for output OUT 1 Changeover of the switching function 1 To change the switching function of output O...

Страница 7: ...that is to be taught OUT1 or Analog OUT 1 Press the teach button for 2s to activate teach mode The yellow LED OUT 1 flashes at 1Hz While in this state output OUT 1 can be taught 2 To teach output Ana...

Страница 8: ...ning range of 400mm 90mm scanning range of 1600mm 310mm 2 To adjust analog output Analog OUT press the teach button for 2 7s until the blue and green LEDs flash simultaneously at 3Hz 3 Release the but...

Страница 9: ...of the same type are wired together in a network according to the following diagram The devices work in synchronous operation with a simultaneous transmission pulse The response time of the individual...

Страница 10: ...factory setting 1 switching point at 400mm or 1600mm rising characteristic curve with spread over the entire scanning range Resetting to factory settings 1 When switching on the supply voltage during...