PROFINET
Leuze electronic
DCR 248i
82
Output data
Address
Data type
Value range
Default
Unit
Explanation
New entry
0.5
Bit
0 -> 1: New entry
1 -> 0: New entry
0
---
The toggle bit shows
whether new entry data
is present
Reserved
0.6
Bit
0
---
Free
0.7
Bit
0
---
Free
Entry data
length
1
UN-
SIGNED16
0-65535
0
---
Data length of the ac-
tual information.
Data
3..258
256x
UN-
SIGNED8
0-FFh
0
---
Information with a
length of consistently
256 bytes.
Output data length: 3 bytes consis 356 bytes of result information
10.4.21 Module 60 - Device status and control
PROFINET-IO module identifier
• Module ID: 1060
• Submodule ID: 1
Description
The module contains the display of the device status as well as control bits for triggering a reset or putting
the device into standby mode.
Tab. 10.32:
Input data structure module 60
Input data
Address
Data type
Value range
Default
Unit
Explanation
Device status 0
UN-
SIGNED 8
10: Standby
11: Service
15: Device is
ready
0x80: Error
0x81: Warning
0
---
This byte represents
the device status.
Input data length: 1 byte
Tab. 10.33:
Output data structure module 60
Output data
Address
Data type
Value range
Default
Unit
Explanation
Reserved
0.0
Bit
0
---
Free
Error ac-
knowledge
0.1
Bit
0->1: Error Ac-
knowledge
1->0: Error Ac-
knowledge
0
---
This control bit con-
firms and deletes er-
rors or warnings that
may be present in the
system.
It acts like a toggle bit.
Reserved
0.2-0.5
Bit
0
---
Free
System reset 0.6
Bit
0: Run
0->1: Reset
0
---
The control bit triggers
a system reset if the
level changes from 0 to
1.
Standby
0.7
Bit
0: Standby off
1: Standby on
0
---
Activates the standby
function
Output data length: 1 byte