Starting up the device - Configuration
Leuze electronic
BCL 600i/BCL 601i
53
In the webConfig tool
In the main menu, select Configuration -> Communication -> Overview.
Or alternatively in the display
In the main menu, select the Parameter menu.
Select the Com menu item.
Press the enter button to enter the menu.
Select the Operating mode menu item.
Press the enter button to enter the menu.
Select the desired menu item: Stand-alone device, Network master or Network slave.
Press the enter button to activate the operating mode.
webConfig tool or display
Set one of the following three operating modes:
• Stand-alone device:
BCL 600i in stand-alone operation (see chapter 10.5)
• Network Master:
BCL 600i as master in multiNet plus. Further settings are required for master operation (see
• Network Slave:
BCL 600i as slave in multiNet plus. Further settings are required for slave operation. The configura
-
tion of the BCL 600i as multiNet slave corresponds to the configuration of the BCL 601i (see
10.3.3 Operation as multiNet plus master
For operation as multiNet plus master, you must inform the BCL 600i of the maximum number of slaves
to be managed. This is done via the Maximum number of slaves parameter.
Set the Maximum number of slaves parameter to the desired value:
Via webConfig:
Configuration -> Communication -> BUS OUT -> Protocol
Or, alternatively, via the display:
BCL 600i as slave in multiNet plus. Further settings are required for slave operation. The configuration of
the BCL 600i as multiNet slave corresponds to the configuration of the BCL 601i (see chapter 10.4).
In the main menu, select the Parameter menu.
Select the Com menu item.
Press the enter button to enter the menu.
Select the BUS OUT menu item.
Press the enter button to enter the menu.
Select the multiNet master menu item.
Press the enter button to enter the menu.
Press the enter button to enter the menu for setting the maximum number of slaves.
Displayed in the following screen is the preset number 1, which you can now change.
Select the desired number of slaves. An accidental, incorrect entry can be corrected by selecting <-| and
then pressing the enter button.
Select Save.
Press the enter button in order to save the set number of slaves.
Use the navigation buttons
to move through the menu. Activate the desired selection with
the enter button .