Starting up the device - Configuration
Leuze electronic
BCL 600i/BCL 601i
55
Select the Com menu item.
Press the enter button to enter the menu.
Select the BUS OUT menu item.
Press the enter button to enter the menu.
Select the multiNet Slave menu item.
Press the enter button to enter the menu.
Press the enter button to enter the menu for setting the slave address.
Displayed in the following screen is the preset slave address 1, which you can now change.
Select the desired number of slaves. An accidental, incorrect entry can be corrected by selecting <-| and
then pressing the enter button.
Select Save.
Press the enter button in order to save the set number of slaves.
10.5 Further settings
After the basic configuration of the operating mode and the communication parameters, you need to carry
out further settings:
• Decoding and processing the read data
• Control of the decoding
• Control of the switching outputs
10.5.1 Decoding and processing the read data
The device offers the following possibilities:
• Setting the number of labels to be decoded for each reading gate (0 … 64). This is done via the Max.
no. of labels parameter.
• Definition of up to 8 different code types (4 different types if configured via the display). Labels that
match one of the defined code types are decoded. Further parameters can be set for each code
type:
• Code type (symbology)
• Number of digits: either up to 5 different numbers of digits (e.g., 10, 12, 16, 20, 24), or a range
(Interval mode) and up to three additional numbers of digits (e.g., 2 … 10, 12, 16, 26)
• Reading reliability: the set value specifies how many times a label must be read and decoded with
the same result before the result is accepted as valid.
• Activation of the code reconstruction technology (CRT, in the webConfig tool only)
• Additional code type specific settings (in the webConfig tool only)
• Check digit method used for decoding as well as the type of check digit transmission for the output
of the read result. The two possibilities for the latter are Standard (corresponds to the standard for
the selected code type/symbology) and not Standard.
Define at least one code type with the desired settings.
In the webConfig tool: Configuration -> Decoder
Or alternatively in the display: Parameter -> Decoder table
Permissible values for the network address in the Leuze multiNet plus are 0 … 31. Make certain
that a different address is assigned to each multiNet plus participant.
From the hardware address (device address > 0), the BCL 601i detects that networking is
required. It automatically switches to the Leuze multiNet plus network and waits for initialization
by the master.