x
Reading field distance [mm]
z
Reading field height [mm]
a
Swivel range, ± 20°
1
Module = 0.3 mm: 600 mm - 1050 mm (450 mm depth of field)
2
Module = 0.35 mm: 500 mm - 1200 mm (700 mm depth of field)
3
Module = 0.5 mm: 450 mm - 1450 mm (1000 mm depth of field)
Figure 15.10:Lateral reading field curve - Low Density for oscillating-mirror scanner
15.7 Reading field curves for heating devices
The reading field curves of the heating devices differ to some extent from the normal reading curves due
to the optics heating and are somewhat reduced in the reading field width as well as in the reading field
height!
• The maximum opening angle for all oscillating mirror devices of the BCL 600i series is reduced to
±28° (without heating = ±30°).
• In addition, the maximum swivel range for all oscillating mirror devices of the BCL 600i series is
reduced to ±12° (without heating = ±20°).
• The reading field curves and opening angles are unchanged for all line scanners with heating of the
series BCL 600i.
For details, please refer to the following reading field curves for the heating devices.