PROFINET interface
81
AMS 348
i
Leuze electronic
Parameters
Input data
Output data
None
Parameter
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Velocity
resolution
The parameter specifies the resolution
for the velocity value.
0.0
…
0.2
Bit
001=1: 1
010=2: 10
011=3: 100
100=4: 1000
101 = 5: free resolution
1
mm/s
(in/
100)
/s
20b
Average
The parameter specifies the integration
time (averaging time) of the calculated
velocity values.
0.3
…
0.5
Bit
000=0: 2
001=1: 4
010=2: 8
011=3: 16
100=4: 32
101=5: 64
110=6: 128
3
ms
–
Parameter length: 2 bytes
a
b
Input data
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Velocity
Current velocity.
0
sign
32 bit
-999999
… +999999
0
scaled
–
Input data length: 4 bytes consistently
c