PROFINET interface
Leuze electronic
AMS 348
i
50
TNT
35/7-2
4
V
9
PROFINET interface
9.1
General information on PROFINET
The AMS 348
i
is designed as a PROFINET-RT (Real Time) device (acc. to IEEE 802.3). It
supports a transmission rate of up to 100 Mbit/s (100Base TX/FX), full duplex, as well as
auto-negotiation and auto-crossover.
The functionality of the device is defined via parameter sets which are organized in modules.
The modules form part of the GSD file.
Each AMS 348
i
has a unique MAC-ID which is described on the name plate. This is linked
to an IP address during the course of configuration. In the Simatic Manager for creation of
PROFINET networks, the IP address is also linked to a freely selectable device name which
may only exist once in the network (see chapter 9.8.4.7 "Step 3 – Hardware configuration
of the S7 PLC: Configuration").
9.2
Identification & Maintenance Functions
The AMS 348
i
supports the base record I&M0:
Table 9.1:
Base record I&M0
Contents
Index
Data type
Description
Value
Header
0
10 bytes
Manufacturer specific
-
MANUFACTURER_ID
10
UNSIGNED16
Leuze manufacturer ID
338
ORDER_ID
12
ASCII string 20 bytes
Leuze order no.
-
SERIAL_NUMBER
32
ASCII string 16 bytes
Unique device serial number
Device-
dependent
HARDWARE_REVISION
48
UNSIGNED16
Hardware revision number, e.g.,
"0…65535"
Device-
dependent
SOFTWARE_REVISION
50
1xCHAR, 3xUNSIGNED8
Software version number, e.g.
V130 correspond to "V1.3.0"
Device-
dependent
REVISION_COUNTER
54
UNSIGNED16
Is incremented when updating
individual modules. This function
is not supported.
0
PROFILE_ID
56
UNSIGNED16
PROFINET application profile
number
0xF600 (Generic
Device)
PROFILE_SPECIFIC_TYPE
58
UNSIGNED16
Info about subchannels and
submodules. Not relevant
0x01,0x01
IM_VERSION
60
2xUNSIGNED8
Implemented I&M version V 1.1 0x01,0x01
IM_SUPPORTED
62
Bit[16]
Optional I&M records available
0