![Leuze electronic AMS 348i SSI Скачать руководство пользователя страница 102](http://html.mh-extra.com/html/leuze-electronic/ams-348i-ssi/ams-348i-ssi_original-operating-instructions_1883971102.webp)
PROFINET interface
Leuze electronic
AMS 348
i
SSI
99
TNT
35/7-2
4
V
Notice!
Resolution and maximum position value which can be represented:
Figure 9.18: SSI interface - resolution and maximum position value which can be represented
SSI setting
Max. distance which can be represented
metric
Max. distance which can be represented
inches (in)
24-bit; resolution 0.1
1,677m
16,777in
≈
426m
24-bit; resolution 0.01
167m
1,677in
≈
42m
24-bit; resolution 0.001
16m
167in
≈
4m
25-bit; resolution 0.1
3,355m
33,554in
≈
852m
25-bit; resolution 0.01
335m
3,355in
≈
85m
25-bit; resolution 0.001
33m
335in
≈
8m
26-bit; resolution 0.1
6,710m
67,108in
≈
1,704m
26-bit; resolution 0.01
671m
6,710in
≈
170m
26-bit; resolution 0.001
67m
671in
≈
17m