Fast commissioning / operating principle
Leuze electronic
AMS 308
i
13
TNT
35/7-2
4
V
3.5
Commissioning of the AMS 308
i
3.5.1
Manually setting the IP address
Notice!
To set the network addresses, parameter enabling must be activated, as described in chapter
8.4.
If your system does not include a DHCP server or if the IP addresses of the devices are to
be set permanently, proceed as follows:
Have the network administrator specify the data for IP address, net mask and gateway
address of the AMS 308
i
.
Set these values on the AMS 308
i
.
The menu structure of the display entry can be found at the end of the manual. Call up the
corresponding menu levels and enter the respective addresses.
3.5.2
Automatically setting the IP address
If your system includes a DHCP server that is to be used to assign the IP addresses, observe
the following:
DHCP address assignment is deactivated by default. To activate DHCP address
assignment, parameter enabling must first be activated, see chapter 8.4.
The menu structure of the display entry can be found at the end of the manual. Call up the
corresponding menu levels to activate DHCP.
Further information on entering address data can be found in chapter 9.
3.5.3
Defining Ethernet host communication
The AMS 308
i
can communicate via TCP/IP or UDP. Standard is TCP/IP. If communication
should be via UDP, the "UDP" protocol must be activated via the display in the "Ethernet"
- "Host communication" submenu. UDP and TCP/IP can be activated simultaneously and
used in parallel.
If you would like to use the TCP/IP protocol for your application, you must also define
whether the AMS 308
i
is to operate as a TCP client or as a TCP server.
Contact your network administrator to determine which communication protocol is used.