Device parameters and interfaces
Leuze electronic
AMS 200
4
3
TNT
3
5/7-2
4
V
Notice
!
All input and output modules described in this documentation are described
from the per-
spective of the control
:
Described inputs (I) are inputs of the control.
Described outputs (O) are outputs of the control.
Described parameters (P) are parameters of the GSD file in the control.
Notice
!
The
current GSD file
for the AMS 200… can be found on our homepage under:
www.leuze.com
-> Download -> Identify -> Optical distance measuring and positioning ->
GSD files AMS 200
8
.1.5
Overview of the GSD modules
Module
Module name
Module contents
(P) = Parameter, (O) = Output, (I) = Input
M1
Position value
(I) Position value
(P) Sign
(P) Unit
(P) Resolution
(P) Count direction
(P) Offset
M2
Static preset
(P) Preset value
(O) Preset teach
(O) Preset reset
M
3
Dynamic preset
(O) Preset value
(O) Preset teach
(O) Preset reset
M4
I/O 1
(P) Output or input defined
(P) Level/edge input/output
(P) Function for output wiring
(P) Function for input wiring
(I) Signal level input/output
(O) Output activated
M5
I/O 2
(P) Output or input defined
(P) Level/edge input/output
(P) Function for output wiring
(P) Function for input wiring
(I) Signal level input/output
(O) Output activated
M6
Status and control
(I) Diagnosis and status of AMS 200
(O) Laser control ON/OFF
M7
Position limit value 1
(P) Upper and lower position limit value
M
8
Position limit value 2
(P) Upper and lower position limit value