Device parameters and interfaces
48
AMS 200
Leuze electronic
8
.1.6.2
Module 2: Static preset
Description
With this module, a preset value can be specified. The specified preset value becomes
active in the position in which preset teaching is performed.
Notice
!
In the event of a device change the preset value is retained in the PROFIBUS manager. The
activation of the preset value (preset teach) at the intended position must, however, be per-
formed again.
Parameter
Hex coding of the "preset value" parameter
The value listed in this table shows the hex coding of the default settings:
Input data
none
Output data
Parameter
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr. inch
Preset
Preset value.
The value is accepted during a
corresponding teach event (see
output data).
The parameter applies to all
interfaces. The resolution of the
preset value is independent of
the resolution selected in
module 1.
0
sign
3
2 bit
-999999 … +999999
0
mm
in/
100
2b
4d
5d
Parameter length: 4 bytes
a
Modul
e
ad
dress
P
re
set v
a
lue
02
00 00 00 00
Output
data
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr. inch
Preset
teach
Read in the preset value.
0.0
Bit
0
Æ
1 Preset teach
–
–
4d
5d
Preset
reset
Preset value is deactivated.
0.1
Bit
0
Æ
1 Preset reset
–
–
4d
5d
Output data length: 1 byte
b
c