Device parameters and interfaces
50
AMS 200
Leuze electronic
8
.1.6.4
Module 4: I/O 1 Input/Output
Description
The module defines the mode of operation of the digital input/output
I/O 1
.
Parameter
Parameter
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr. inch
Function
The parameter defines whether
I/O 1
functions as an input or as
an output.
0.0
Bit
0: Input
1: Output
1
–
4cd
Activation
The parameter defines the level
of the output when the "output"
event is received. If
I/O 1
is con-
figured as an input, the response
is edge-controlled.
0.1
Bit
0: Low
1-0 transition
1: High
0-1 transition
0
–
–
Output
The parameter defines which
event triggers activation of the
output. The individual functions
are
OR
-linked to one another.
–
4a
Position limit value 1
If the position value lies outside
of configured limit range 1, the
output is set.
1.0
Bit
0 = OFF
1 = ON
0
–
Position limit value 2
If the position value lies outside
of configured limit range 2, the
output is set.
1.1
Bit
0 = OFF
1 = ON
0
–
Velocity limit value
If the velocity value lies outside of
the configured values, the output
is set. Monitoring from modules
11 to 15 is OR-linked.
1.2
Bit
0 = OFF
1 = ON
0
–
Intensity (ATT)
If the intensity of the received
signal is less than the warning
threshold, the output is set.
1.
3
Bit
0 = OFF
1 = ON
0
–
Temperature (TMP)
If the internal device temperature
exceeds the set limit value, the
output is set.
1.4
Bit
0 = OFF
1 = ON
0
–
Laser (LSR)
Laser prefailure message.
1.5
Bit
0 = OFF
1 = ON
0
–
Plausibility (PLB)
If implausible measurement val-
ues are diagnosed, the output is
set.
1.6
Bit
0 = OFF
1 = ON
1
–
a
b