EN
19
Technical data
NOTICE
Technical data
Additional specifications and notices for using the device can be found in the
operating instructions.
Operating voltage
1)
1) For UL applications: only for use in "Class 2" circuits in accordance with NEC, supply
by means of LPS (Limited Power Source)
20 … 30VDC (PELV, Class 2)
Current consumption
0.72A /
1.3A (when starting up the motor)
Light source / Wavelength
Laser / 630… 680nm
Laser class
2 (in accordance with IEC 60825-1:2007), see
Scanning rate
1000 scans/s
Reading distance
M
-optics: max. 1700mm,
N
-optics: max. 1525mm,
see operating instructions
Resolution
M
-optics: m = 0.33 … 0.51mm (13 … 20mil),
N
-optics: m = 0.25 … 0.38mm (10 … 15mil)
Code types
2/5 Interleaved, Code 39, Code 128, EAN 128,
EAN/UPC, EAN Addendum, Codabar, Code 93,
Interface type
RS 232, RS 422 Full Duplex,
Ethernet TCP/IP, EtherNet/IP, PROFINET-IO
Auxiliary interface
RS 232
Switching inputs
3 (optical coupler, see operating instructions)
Switching outputs
2, configurable (see operating instructions)
Degree of protection
IP 65
2)
2) Only if M12 plugs are screwed into place and sealing caps are mounted
VDE safety class
II
Housing
Diecast aluminum
Weight
Approx. 2kg
Dimensions
See
Ambient temp.
operation/storage
0°C … +50°C / -20°C … +70°C
Rel. air humidity (non-condensing)
10 … 90%
Ambient light
Max. 30,000 lux
Vibration
IEC 60068-2-6, Test Fc
Shock
IEC 60068-2-27, Test Ea
Electromagnetic compatibility
EN 55022, IEC 61000-6-2
3)
3) This is a Class A product. In a domestic environment this product may cause radio
interference, in which case the operator may be required to take adequate measures.
Conformity
CE, CDRH
Certifications
UL 60950-1, CSA C22.2 No. 60950-1
1)