background image

Friedrich Leutert GmbH & Co. KG 

MSI-3 Operating Instructions, Page 6

11

6

9

8

1

10

12

7

2

5

4c

4a

4b

4d

3

5

5

older version

older version

latest version

latest version

Item

Description

Part-No.

Components

1

Upper part

4645.11.00001

2

Bottom part assembly 

4645.11.00018

3

Valve assembly

4645.99.01000

4a

Spring

4645.11.00006

4b

Ball

4645.11.00005

4c

Valve base

4645.11.00003

4d

Filter

4645.11.00003

4

Valve guide

4645.11.00004

5

Copper seal

9000.00.89123

6

Venting screw

4645.11.00008

7

Pressure gauge 0 – 160 bar

9000.00.91307

Pressure gauge 0 – 250 bar

9000.00.91308

Pressure gauge 0 – 300 bar

9000.00.91309

8

Pressure gauge seal

9000.00.89122

9

Bracket

4645.11.00009

10

Handle

4645.11.00011

11

Hexagonal screw

ISCHRBM05.055

12

Countersunk screw

SSCHRBM06.110

Содержание MSI-3

Страница 1: ...emory Easy handling Cost effective 49 4131 959 0 sales maritime leutert com com Peak Pressure Indicator MSI 3 Operating Instructions Engine Indicator The Leutert Peak Pressure Indicator MSI 3 measures...

Страница 2: ...0 bar Part No 4644 00 00000 250 bar Part No 4645 00 00000 Max working pressure 300 bar Part No 4646 00 00000 Permissible temperature ambient 20 to 60 C meets the regulations of the following directive...

Страница 3: ...el In case of doubt regarding safety or operational aspects please do not hesitate to contact LEUTERT for assistance Should you notice a faulty description or depiction or if you would like to suggest...

Страница 4: ...gauge is mounted on top end of the bottom part The bottom part also houses a shock absorber and a shutoff system The shock absorber regulates and stabilizes the buildup of pressure for the display un...

Страница 5: ...m Description Part No Peak Pressure Indicator MSI 3 MSI 3 160 bar 4644 00 00000 MSI 3 250 bar 4645 00 00000 MSI 3 300 bar 4646 00 00000 Item Description Part No Tools and Accessories 15 Wooden box 464...

Страница 6: ...embly 4645 99 01000 4a Spring 4645 11 00006 4b Ball 4645 11 00005 4c Valve base 4645 11 00003 4d Filter 4645 11 00003 4 Valve guide 4645 11 00004 5 Copper seal 9000 00 89123 6 Venting screw 4645 11 00...

Страница 7: ...low spanner provided to attach or remove indicator from indicator valve Hammering on the extensions of the connecting nut will damage the nut As a result the nut might brake apart and detach itself an...

Страница 8: ...bration every two years Please note that the instrument itself must not get hotter than 60 C WARNING Do not exceed the maximum working temperature of 60 C Detach the indicator immediately from the ind...

Отзывы: