Leto Enterprises Ageless Wonder Скачать руководство пользователя страница 21

 

20 

 

 

10.2 First Operation 

1. Open the battery compartment by sliding the door gently downwards (Please see Figure 1). 

2. Insert 2 x AAA batteries by following the polarity indications in the compartment. (Please see Figure 

1). 

3. Plug the application wand into the control unit. (Please see Figure 2). 

Use the wand attached to the cable, plug it into the device. Please note that without the headset, only 

the wand with the cable will work. We recommend clipping the provided handle into the back of the 

wand when not using the headset. 

 

 

                                       

Figure 1                                                                    Figure 2 

 

 

 

4.  Make  sure  the  device  is  switched  off,  i.e.  the  LCD  display  is  OFF.  If  you  accidentally  switch  the 

device on, press and hold the button                    for 2 seconds to switch it off again. 

5. Choose a program as described in the next paragraph and either hold the application device in your 

hand or insert it into the headset, depending on the area you want to stimulate. 

6.  Switch  the  device  ON  by  pressing  the  button                    once.  The  LCD  display  will  light  up  and 

show the various functions. 

7. Use the M button to toggle through the menu: 

 

 

The device will NOT work unless the sponges in the application wand are wet 

and acting as a conductive medium between your skin and the application wand! 

In  order  to  remove  the  belt  clip,  push  the 

center  area  down  that  is  marked  with  the 

triangular  arrow  to  release  the  lock,  and  at 

the  same  time  pull  the  clip  away  from  the 

unit. 

Содержание Ageless Wonder

Страница 1: ...Leto Enterprises Incorporation Ageless Wonder Facial Muscle Stimulation System User Manual Version V1 0 Release with software version 1 0...

Страница 2: ...2 Device Drawing 5 9 3 Device Components 6 9 4 Panel Keypad 6 9 5 Treatment Modes 7 9 6 Specification 9 10 Operating Instructions 16 10 1 Installation 16 10 2 First Operation 20 10 3 Wand Placement 2...

Страница 3: ...erosis Phlebitis in its active phase inflammation of a vein Inflamed tissue as a result of disease injury or surgery Recent scar tissue or surgery Varicose veins in later stages 4 Adverse Reaction The...

Страница 4: ...cute trauma or following recent surgery 4 Never use the Ageless Wonder Facial Muscle Stimulation System while driving operating machinery or during activities in which involuntary muscle contractions...

Страница 5: ...t The unit displaying this symbol contains a BF Type isolated patient applied part providing protection against shock 9 Product Information 9 1 Product Introduction The Ageless Wonder Facial Muscle St...

Страница 6: ...5 9 2 Device Drawing Front View of Device Back View of Device...

Страница 7: ...dset 3 Two Application wands 4 Press Key See Panel Keypad part in detail 5 LCD Panel 6 Belt Clip 7 Device Label 8 Conductive Sponge 9 Cable 10 Alkaline battery 11 Pluggable Handle 9 4 Panel Keypad Exp...

Страница 8: ...LE ON OFF Press and hold the M button together with the while the device wand is operating and you are in intensity mode The LCD will show the key lock icon Power On Off To turn the power on off 9 5 T...

Страница 9: ...the headset horizontally with the application wands below the cheekbone and approx 1 2 cm in front of the ear Mode 3 Lower Cheek Use the headset for this stimulation mode Select this mode to stimulat...

Страница 10: ...g the provided handle into the back of the wand Select this mode to stimulate the area under your eye 9 6 Specification Basic Information Trade Name Ageless Wonder Facial Muscle Stimulation System Com...

Страница 11: ...e the following information Sound on off Keylock Low battery Active areas and positions Minimum of Workout time Intensity level Mode selection Dimensions Weight Dimension Main Unit 98 5 x 53 x 27 5 mm...

Страница 12: ...Intensity 11 12 13 14 15 16 17 18 19 20 Peak Voltage V 1K 20 4 21 6 23 24 2 26 4 28 2 29 2 30 4 31 6 34 4 Peak Voltage V 0 5K 12 8 13 6 14 4 15 2 16 6 17 2 18 2 18 8 19 8 21 2 Intensity 21 22 23 24 25...

Страница 13: ...6 88 7 2 7 44 Intensity 11 12 13 14 15 16 17 18 19 20 Peak Voltage V 1K 12 8 13 6 14 6 15 2 16 2 17 4 18 6 19 8 20 8 22 Peak Voltage V 0 5K 7 92 8 4 8 96 9 44 9 84 10 6 11 2 11 8 12 4 13 2 Intensity 2...

Страница 14: ...08 8 64 Intensity 11 12 13 14 15 16 17 18 19 20 Peak Voltage V 1K 15 16 2 16 8 18 2 20 2 21 4 22 8 24 2 25 4 27 Peak Voltage V 0 5K 9 04 9 68 10 2 11 12 12 8 13 8 14 4 15 6 16 4 Intensity 21 22 23 24...

Страница 15: ...7 12 7 36 Intensity 11 12 13 14 15 16 17 18 19 20 Peak Voltage V 1K 13 13 8 14 6 15 6 16 4 17 6 18 8 20 20 8 22 Peak Voltage V 0 5K 7 92 8 32 8 88 9 12 9 84 10 6 11 1 11 8 12 4 13 2 Intensity 21 22 23...

Страница 16: ...8 08 8 48 Intensity 11 12 13 14 15 16 17 18 19 20 Peak Voltage V 1K 15 4 16 4 17 4 18 6 20 4 21 4 22 8 24 25 6 26 6 Peak Voltage V 0 5K 9 12 9 76 10 2 10 7 12 13 13 6 14 6 15 6 16 2 Intensity 21 22 23...

Страница 17: ...ty 11 12 13 14 15 16 17 18 19 20 Peak Voltage V 1K 20 6 22 23 24 26 6 28 29 4 30 8 32 34 8 Peak Voltage V 0 5K 12 6 13 6 14 4 15 2 16 4 17 2 18 18 8 19 8 21 2 Intensity 21 22 23 24 25 26 27 28 29 30 P...

Страница 18: ...er 3 Place the conductive sponges onto the wand and press to fix the silicon on top 4 Finished 5 Now use the small bottle to drip water until the sponge is wet to the touch Repeat on the 2nd applicati...

Страница 19: ...dicated in the LCD display 5 Remove the application wand from the headset for handheld operation and push the wand with the cable attached lightly towards the center of the headset until it pops out 6...

Страница 20: ...the inserted application wands and after wetting the sponges place it from behind your head onto your face For program mode 1 and 2 the correct positioning is directly under your cheek bone a little b...

Страница 21: ...display is OFF If you accidentally switch the device on press and hold the button for 2 seconds to switch it off again 5 Choose a program as described in the next paragraph and either hold the applic...

Страница 22: ...pplication wand will vary from person to person The ideal positioning is adjacent to the motor nerve While the device is operating you will be able to move the application wand to find the most effect...

Страница 23: ...e button once to increase or decrease the time increment Maximum time is 20 minutes 1 To switch the device off press and hold the button for 2 seconds The Ageless Wonder Facial Muscle Stimulation Syst...

Страница 24: ...ist to the touch Gradually increase the PULSE INTENSITY by pushing the button until muscle contraction is felt The Ageless Wonder Facial Muscle Stimulation System is a great way to tone lift and firm...

Страница 25: ...up but nothing occurs Intensity set to low level Sponge is not wet enough the wands are positioned incorrectly Sponge has oil deposits Battery is low Choose mode and Increase intensity by pushing the...

Страница 26: ...eel any unpleasantness At low intensity you will feel a slight tingling sensation but as the intensity gets higher you will only feel pleasant contractions However should you feel irritation or contin...

Страница 27: ...nts so avoid vibration during transport Keep the device at a normal temperature and avoid prolonged sun exposure during transport 15 Warranty Period Ageless Wonder Facial Muscle Stimulation System war...

Страница 28: ...nance card 1 6 Warranty Card 1 7 Pluggable Handle 1 Company Leto Enterprises Incorporation ADD 19 F Nan Dao Commercial Building 359 361 Queen s Road Central Hong Kong China Tel 852 3694 0110 Fax 852 2...

Страница 29: ...failure to follow instructions or warnings in owner s manual or use of products in a manner for which they were not designed THIS WARRANTY DOES NOT APPLY TO THE FOLLOWING 1 Damage due to accident misu...