2
2.1.1 Install receiver
Follow the installation diagrams to install and connect the receiver
L
TR10 correctly.
Note: 1
The installation and wiring should be operated by trained personnel.
Note: 2
The Receiver should be mounted in a suitable location that is both accessible for
the connection of mains and control wiring, and allows good reception of the RF
signal. The Receiver needs a 100~240 V AC mains supply to operate, and this
should be fused appropriately (5 A max.).
Note: 3
The Receiver should be mounted in a location where it will not come into contact
with water, moisture or condensation.
2. System Installation
2.1 Install and wiring receiver
Loosen the screw on the
receiver’s bottom. (No need
to screw out completely)
Fasten the terminal base
on wall with 4 screws
Loosen the screws on terminals,
wiring the terminal correctly, then
fasten the screws
Open the upper cover