legible, do not use the battery.  Refer to your dealer
if you do not understand what type battery you are
using and have them set the "BATTERY TYPE"
switch accordingly.

The "BATTERY TYPE" switch is a two-position slide
switch visible in the rectangular opening on the front
of the charger.  Using a small screwdriver, slide the
switch from one setting to the other through the
opening.  Take care not to damage the switch when
moving it to the desired setting.

NORMAL OPERATION

Instructions printed on cover of charger are for
daily reference.

1.

Set "BATTERY TYPE" switch to the proper style
of battery to be charged.

CAUTION:  MAKE SURE THE BATTERY

PACK IS A 24-VOLT, 12 CELL, SERIES
CONNECTED, 50-120 AMP-HOUR (20 HR. RATE),
AND RECHARGEABLE DEEP-CYCLE BATTERY
SYSTEM.  THE "GEL CELL AND SEALED DEEP-
CYCLE BATTERY" SETTING CHARGES TO A
MAXIMUM ON-CHARGE VOLTAGE OF 2.38
VOLTS PER CELL.  THE "REPLACEABLE
ELECTROLYTE DEEP-CYCLE BATTERY"
SETTING HAS AN ON-CHARGE VOLTAGE OF AT
LEAST 2.50 VOLTS PER CELL.  VISUALLY
CHECK THAT THE "BATTERY TYPE" SWITCH IS
SET CORRECTLY FOR THE TYPE OF BATTERY
YOU ARE USING.

DANGER:  TO PREVENT ELECTRICAL

SHOCK, DO NOT TOUCH UNINSULATED PARTS
OF THE CHARGER DC OUTPUT CONNECTOR,
BATTERY CONNECTOR, OR BATTERY
TERMINALS.  MAKE SURE ALL ELECTRICAL
CONNECTORS ARE IN GOOD WORKING
CONDITION.  DO NOT USE CONNECTORS THAT
ARE CRACKED, CORRODED OR DO NOT MAKE
ADEQUATE ELECTRICAL CONTACT.  USE OF A
DAMAGED OR DEFECTIVE CONNECTOR MAY
RESULT IN A RISK OF OVERHEATING OR
ELECTRIC SHOCK.

2.

Move the "POWER" switch to "OFF" position.

3.

Connect the power supply cord to a properly
grounded single-phase outlet that matches the
voltage setting on the AC voltage selector
switch.

4.

Connect charger's DC output plug to the
equipment-charging receptacle.  Do not connect
the DC plug unless the "POWER" switch is in
the "OFF" position.

CAUTION:  MANY DC PLUGS DO NOT HAVE

A STANDARDIZED WIRING PATTERN.  VERIFY
THAT THE CHARGER PLUG WIRING PATTERN
MATCHES THE EQUIPMENT BEING CHARGED
BEFORE CONNECTING.  DAMAGE MAY RESULT
IF A PLUG THAT IS WIRED FOR OTHER
APPLICATIONS IS USED ON YOUR EQUIPMENT.
CONTACT YOUR DEALER OR THE EQUIPMENT
MANUFACTURER FOR MORE INFORMATION.

5.

Move the "POWER" switch to "ON" and the RED
and GREEN lights will come on steady for a few
seconds to test the lights.  If the lights do not
come on, either the AC cord is not plugged in or
the AC outlet is not live.  Test for a live AC outlet
by connecting a suitable appliance into the
specific outlet.

WARNING:  CHARGER IS NOT TO BE USED

WHILE THE EQUIPMENT IS OPERATING.

ATTENTION:  Ne pas utiliser le charger

pendant que l'equipment est en marche.

WARNING:  LEAD-ACID BATTERIES

GENERATE GASES, WHICH CAN BE
EXPLOSIVE.  TO PREVENT ARCING OR
BURNING NEAR BATTERIES, DO NOT
DISCONNECT DC CHARGING CORD FROM
BATTERIES WHEN THE CHARGER IS
OPERATING.  IF THE CHARGE CYCLE MUST BE
INTERRUPTED, MOVE THE "POWER" SWITCH
TO "OFF", AND DISCONNECT THE CHARGER
POWER SUPPLY CORD BEFORE
DISCONNECTING THE DC OUTPUT CORD FROM
THE BATTERIES.  KEEP SPARKS, FLAME, AND
SMOKING MATERIALS AWAY FROM
BATTERIES.

WARNING:  ALWAYS SHIELD EYES WHEN

WORKING NEAR BATTERIES.  DO NOT PUT
WRENCHES OR OTHER METAL OBJECTS
ACROSS BATTERY TERMINAL OR BATTERY
TOP.  ARCING OR EXPLOSION OF THE
BATTERY CAN RESULT!

Charger will output power three to five (3-5)
seconds after turning switch "ON" as indicated
by the RED light turning off, the slow blinking
GREEN light (once per second), and a slight
transformer hum.

If both lights go off about five seconds after AC
is applied, check to see if the DC plug is
correctly connected to the battery.  If the DC
plug is connected properly, either an open circuit
exists in the equipment's internal circuitry, or the
battery voltage is below seven (7) volts (see
Troubleshooting).

Содержание 18830

Страница 1: ...justable to charge gel cell and sealed or conventional replaceable liquid electrolyte deep cycle lead acid batteries A switch on the front of the charger selects different charge characteristics Patented electronic circuit monitors battery state of charge and automatically turns charger off when the batteries reach full charge Line voltage compensation produces consistent charger output for AC sup...

Страница 2: ...o not allow clothing blankets or other material to cover charger WARNING CHARGERS CAN IGNITE FLAMMABLE MATERIALS AND VAPORS DO NOT USE NEAR FUELS GRAIN DUST SOLVENTS THINNERS OR OTHER FLAMMABLES WARNING KEEP DRY DO NOT EXPOSE TO RAIN OR SPRAY FOR STORAGE KEEP IN A BUILDING REPLACE WORN CUT OR DAMAGED ELECTRICAL CORDS AND PLUGS IMMEDIATELY AC INPUT AND GROUNDING INSTRUCTIONS The charger must be con...

Страница 3: ...tacle Do not connect the DC plug unless the POWER switch is in the OFF position CAUTION MANY DC PLUGS DO NOT HAVE A STANDARDIZED WIRING PATTERN VERIFY THAT THE CHARGER PLUG WIRING PATTERN MATCHES THE EQUIPMENT BEING CHARGED BEFORE CONNECTING DAMAGE MAY RESULT IF A PLUG THAT IS WIRED FOR OTHER APPLICATIONS IS USED ON YOUR EQUIPMENT CONTACT YOUR DEALER OR THE EQUIPMENT MANUFACTURER FOR MORE INFORMAT...

Страница 4: ...a safe temperature it will automatically restart If charger repeatedly overheats refer to a qualified service agent 8 Charger turns off automatically when batteries are fully charged as indicated by steady on GREEN light Charge time varies with battery size and depth of discharge Allow 8 hours for normal charging Larger batteries greater than 150 ampere hours or severely discharged batteries may r...

Страница 5: ... should be within range of your voice or close enough to come to your aid when you work near a lead acid battery 2 Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes 3 Wear complete eye protection and clothing protection Avoid touching eyes while working near battery 4 If battery acid contacts skin or clothing wash immediately with soap and water If acid...

Страница 6: ...cuit has high resistance corroded or loose connections loose or worn charging receptacle and loose or worn fuseholders 4 A decrease in equipment range where it loses power earlier and earlier in the day indicates one of the following a Use of the equipment before the batteries have been fully charged and the charger turns off shortens battery life and hastens the onset of this reduced daily range ...

Страница 7: ... more than 16 hours to charge c Very deeply discharged batteries 100 discharged can require more than 16 hours to charge d Several failed cells in the batteries that do not allow the charge rate to taper below 4 amps 7 If battery voltage exceeds 2 83 volts per cell the charger turns off and the RED light begins to slow blink indicating one of the following a Improper batteries used with charger Mu...

Страница 8: ...R SWITCH 15739S 2 SWITCH 115 230 VOLTAGE SELECTION 18363S 1 BUSHING STRAIN RELIEF FOR DC CORD 23666S 1 CORDSET AC 1 0 mm IEC 320 CONT EUROPE 23667S 1 CORDSET AC 1 0 mm 96 IEC 320 CONT U K 24327S 1 CORDSET AC 18 3 96 IEC 320 5 15P 23668S 1 CORDSET AC 2 0 mm IEC 320M JAPAN 26054S 1 CORDSET DC 14 2 108 W SB50 RED PLUG 27704S 1 CORDSET DC 14 2 108 W 30 AMP POWER POLE 24286S 1 CORDSET DC 14 2 108 W SB5...

Страница 9: ...ory to the owner will be paid for by the owner All warranty work accomplished at the Lester factory will be completed with a reasonable time after receipt of defective items This warranty does not cover any semiconductor parts such as diodes which are vulnerable to electrical overloads beyond the control of Lester Warranty on parts not manufactured by Lester which include but are not limited to ti...

Отзывы: