Operating Instructions
3
00949U
have removable cell caps. Water electrolyzed by
discharging and charging the battery is replaced
through these openings.
Gel cell and sealed "maintenance-free" batteries are
generally distinguished by non-removable cell caps.
The physical appearance of battery case is
frequently the same as that of a conventional liquid
electrolyte battery though the cell caps are generally
not removable.
Refer to the battery manufacturer’s information
panel on the battery case to determine the type
battery you have. If the information panel is missing
or not legible, do not use the battery. Refer to your
dealer if you do not understand what type of battery
you are using and have them set the BATTERY
TYPE switch accordingly.
The BATTERY TYPE switch is a two-position slide
switch visible at the opening in the front panel of the
electronic timer assembly. Slide the switch from
one setting to the other through the opening. Take
care not to damage the switch when moving it to the
desired setting.
CHARGING
FAULT
SET HERE FOR
GEL CELL, SEALED OR
MAINT. FREE BATTERIES
SET HERE FOR
CONVENTIONAL LIQUID
ELECTROLYTE BATTERIES
U.S. PAT. NO. 3,794,905
GR. BR. PAT. NO. 1,414,359
FR. PAT. NO. 2,203,199
W. GR. PAT. NO. 2,351,559
JAPAN PAT. NO. 33133/1978
YELLOW INDICATOR
LIGHT
RED INDICATOR
LIGHT
BATTERY TYPE
SWITCH
NORMAL OPERATION
Instructions printed on cover of charger are for
daily reference.
1.
Connect charger DC output cord to the
wheelchair charging receptacle. Do not connect
the DC plug unless the Power switch is in the
"OFF" position and the power supply cord is
disconnected.
CAUTION: MAKE SURE THE BATTERY
PACK IS A 24 VOLT, 12 CELL, SERIES
CONNECTED, 28-85 AMP-HOUR (20 HR. RATE),
RECHARGEABLE DEEP-CYCLE BATTERY
SYSTEM. THE "GEL CELL AND SEALED DEEP-
CYCLE BATTERY" SETTING CHARGES TO A
MAXIMUM ON CHARGE VOLTAGE OF 2.35
VOLTS PER CELL. THE "REPLACEABLE
ELECTROLYTE DEEP-CYCLE BATTERY"
SETTING HAS AN ON CHARGE VOLTAGE OF
AT LEAST 2.50 VOLTS PER CELL. VISUALLY
CHECK THAT THE "BATTERY TYPE" SWITCH IS
SET CORRECTLY FOR THE TYPE OF BATTERY
YOU ARE USING.
DANGER: TO PREVENT ELECTRIC SHOCK,
DO NOT TOUCH UNINSULATED PARTS OF THE
CHARGER DC OUTPUT CONNECTOR, BATTERY
CONNECTOR, OR BATTERY TERMINALS.
MAKE SURE ALL ELECTRICAL CONNECTORS
ARE IN GOOD WORKING CONDITION. DO NOT
USE CONNECTORS THAT ARE CRACKED,
CORRODED OR DO NOT MAKE ADEQUATE
ELECTRICAL CONTACT. USE OF A DAMAGED
OR DEFECTIVE CONNECTOR MAY RESULT IN A
RISK OF OVERHEATING OR ELECTRIC SHOCK.
2.
Connect the power supply cord to a properly
grounded, 120 volt, 60 Hertz single phase
outlet.
3.
Move the POWER switch to "AUTO". The
ammeter needle may bounce initially and the
transformer should hum slightly.
WARNING: CHARGER IS NOT TO BE USED
WHILE THE EQUIPMENT IS OPERATING.
ATTENTION: Ne pas utiliser le charger
pendant que l'equipment est en marche.
WARNING: LEAD-ACID BATTERIES
GENERATE GASES WHICH CAN BE
EXPLOSIVE. TO PREVENT ARCING OR
BURNING NEAR BATTERIES, DO NOT
DISCONNECT DC CHARGING CORD FROM
BATTERIES WHEN THE CHARGER IS
OPERATING. IF THE CHARGE CYCLE MUST BE
INTERRUPTED, MOVE THE POWER SWITCH TO
"OFF", AND DISCONNECT THE CHARGER
POWER SUPPLY CORD BEFORE
DISCONNECTING THE DC OUTPUT CORD
FROM THE BATTERIES. KEEP SPARKS,
FLAME, AND SMOKING MATERIALS AWAY
FROM BATTERIES.