background image

Local Navigator Bluetooth Base Station

lesswire AG

Page 8

3.3 

Inquiry and Change of Parameters

Inquiry of the actual setup of the Local Navigator Bluetooth Base Station is performed
by a standard internet browser (Microsoft Internet Explorer or Netscape). Validity of
the  functionality and the network connection is also checked by the browser.

Procedure:

-

 

Check, whether PC and Base Station are connected with the network and
whether the Base Station is up and running (LED4 is switched on).

-

 

Start the internet browser on your PC.

-

 

Type the IP address of the Base Station into the address field of the browser
and press ‘Enter’ or click ‘Go’. The Local Navigator Bluetooth Base Station has
the predefined IP address 172.16.200.86 after shipment.

If the PC can setup a connection with the device, the actual configuration of the Base
Station is displayed by an internet page, as shown by the image 3.3.

Important Notice:

If the Base Station is currently in manual firmware update mode
(LED4 is blinking), access of the configuration is not possible. In
this case, please perform a reset by disconnecting power.

Содержание BS2

Страница 1: ...User Manual Local Navigator Bluetooth Base Station lesswire AG Im Technologiepark 25 D 15236 Frankfurt Oder ...

Страница 2: ... 6 3 OPERATIONAL MODES AND CONFIGURATION 7 3 1 Introduction 7 3 2 Operational Modes of the Base Station 7 3 2 1 Application Mode 7 3 2 2 Firmware Update Mode 7 3 3 Inquiry and Change of Parameters 8 3 4 PPP Server Configuration 10 3 5 Shipment Settings 11 4 FIRMWARE UPDATE 12 4 1 Introduction 12 4 2 Automatic Firmware Update 12 4 3 Manual Firmware Update 14 4 4 Administration of the FTP Server in ...

Страница 3: ...radio interface standard called Bluetooth is dedicated to supply the cost and power efficient installation of high performance radio networks The standard is defined in a way that it can be used worldwide without any country specific adaptations The used radio frequencies are in the license free ISM band which is defined to be between 2 4 and 2 5 GHz The radio transmission power Class 3 1 mW is se...

Страница 4: ...UXACRYL with five control LED s behind and a back made of Aluminium Front view LED1 LED2 LED3 LED4 LED5 LED1 red Ethernet control LED2 yellow Ethernet control LED3 green Ethernet control LED4 green Operation LED5 yellow Status Backside view DC input 6V 500mA for power supply with 2 5 2 1 mm plug inside contact with positive voltage RJ45 plug for 10 100Base TX Ethernet interface IEEE 802 3 ...

Страница 5: ...r supplies with the specified voltage and polarity and which are compliant with the security constraints of your country Disconnect the power supply before opening the housing There are no inside components which need customer maintenance All maintenance change upgrade or repair work has to be performed by specially trained staff When in operation the security distance to the human body is 20cm du...

Страница 6: ...nized 2 Connecting the device with power Power is supplied via an external power supply with the voltage specified in this user manual Please ensure that your facility power supply is compliant with the input power of the AC adapter used The output characteristics of the AC adapter have to be 6V 500mA and need to be connected via a hole connector positive voltage inside Connect the device first wi...

Страница 7: ...ectly and is ready for execution 3 2 2 Firmware Update Mode The user can also configure the Local Navigator Bluetooth Base Station in a way that a firmware update can be performed There are two general options for this procedure one is the automatic firmware update another is the manual firmware update When the automatic firmware update is selected the Base Station starts a FTP client and searches...

Страница 8: ...tion is up and running LED4 is switched on Start the internet browser on your PC Type the IP address of the Base Station into the address field of the browser and press Enter or click Go The Local Navigator Bluetooth Base Station has the predefined IP address 172 16 200 86 after shipment If the PC can setup a connection with the device the actual configuration of the Base Station is displayed by a...

Страница 9: ...n be changed back by the Undo button of the browser When the configuration is finished a click on the Submit Restart button will transfer the data to the Base Station The device will then perform a restart and the new parameters will be used A red status line in the upper view is showing the actual status of the configuration If any bad value is entered and the Submit Restart button is clicked the...

Страница 10: ...ss is known This setting should therefore be indicated on the Base Station e g by an appropriate label 3 4 PPP Server Configuration The PPP server settings are used to define the address area for the Bluetooth clients The first value see Image 3 4 172 16 200 52 is always the IP address of the Base Station as seen from the client side All other addresses can be assigned to Bluetooth clients These c...

Страница 11: ... 254 PPP server settings Static IP address range from 172 16 200 52 to 172 16 200 53 Username Password Firmware update Enable Automatic Firmware Update disabled IP address of FTP server 172 16 200 13 Procedure connect the power supply wait until LED5 yellow starts to blink and disconnect the power supply during the blinking phase reconnect the power supply and disconnect again during the blinking ...

Страница 12: ...start click Submit Restart button in the browser or power up reset to find a FTP server in the network under a pre configured IP address Is this search successful the Base Station starts a FTP client If a FTP server cannot be reached by the configured IP address a restart without firmware update is performed If the FTP server is addressed successfully and the FTP client could be started a download...

Страница 13: ...rts as usual with an initialization phase and LED5 is blinking for appr 3 seconds After that the new application is in execution To leave the automatic firmware update mode the corresponding check box has to be disabled in the dialog and the Submit Restart button has to be clicked Important notice The discovery of new devices can in some networks last a specific time and is not possible in realtim...

Страница 14: ...C in the same network Necessary Configuration on the Local Navigator Bluetooth Base Station First the Base Station has to be configured for manual update as shown in the following image Image 4 31 HTML page for manual firmware update By clicking on the Start Firmware Update button the Base Station starts the manual update mode LED4 green starts to blink and an HTML page as shown by image 4 32 will...

Страница 15: ...e file upload can be started by e g put fwbs2_xxx bin enter if this action is completed a Transfer Complete response and the total number of transferred Bytes and the data transfer rate is displayed type in bye enter to close the FTP session Now the flash programming on the Base Station starts This is indicated by parallel blinking LED4 and LED5 The start of the application again commences with LE...

Страница 16: ...a subdirectory to FTP root a directory with the name bs2 has to be created User lap has to have read and write access capability to this directory As required by the actual scenario a file with the naming fwbs2_xxx bin and containing the firmware update file has to be stored in the subdirectory bs2 The TCP port of the FTP server has to be configured as 21 which is the standard port setup The image...

Страница 17: ...Local Navigator Bluetooth Base Station lesswire AG Page 17 Image 4 42 IIS Default FTP Site Properties Security Accounts ...

Страница 18: ...Local Navigator Bluetooth Base Station lesswire AG Page 18 applying the command Add will add User lap with Password lap as Operator Image 4 43 IIS Add the User ...

Страница 19: ...th Base Station lesswire AG Page 19 Image 4 44 IIS Provide user lap with administrator rights Image 4 45 IIS Specify the ftp root directory as a subdirectory to ftproot the directory bs2 with the file fwbs2_xxx bin is created ...

Страница 20: ...g the username for the Base Station When the command dir is issued the directory bs2 should be displayed By entering the command cd bs2 the directory setting should be changed to bs2 and the file fwbs2_xxx bin should be listed The FTP server is correctly setup for the automatic firmware update when this file is listed The FTP session can be shut down by entering bye at the DOS prompt It is also ve...

Страница 21: ... excluding external power supply Remote Configuration standard Web browser Power Requirements 6 VDC external power supply Power Consumption 500mA 6 Support Warranty Warranty period The warranty period for this product is one 1 year from the date of product purchase Warranty service If you think your product needs servicing refer to our web site for technical support If your product needs a hardwar...

Отзывы: