6
2020.01 / b
Electric Power Generation
Installation and maintenance
LSA PMR 320
Alternator for rail application - 8-pole
5785 en -
• Mechanical checks
Before starting the machine for the first time,
check that:
- all fixing bolts are tight, and there are no
leaks from the water inlet and outlet
,
- the length of bolt and the tightening torque
are correct,
- the protective grille is correctly in place,
- the standard direction of rotation is clock-
wise as seen from the drive end (phase
rotation in order 1 - 2 - 3).
For anti-clockwise rotation, swap 2 and 3.
3.3 - Terminal connection diagrams
Any intervention on the alternator
terminals during checks should be
performed with the machine stopped.
In no case should the internal
connections in the terminal box be
subjected to stresses due to cables
connected by the user.
• Three-phase 12-wire
L1(U)
N
L3(W)
T1
T7
T12
T10
T4
T9
T3
T6
T11
T5
T2
T8
L2(V)
A
3PH
T6
T4
T3
T2
T1
T5
W (3) – L3
V (2) – L2
U (1) – L1
T9
T8
T7
T10
T11
T12
Connection codes
Factory connection
Parallel Star
DE
NDE
OUTPUTS TO THE RIGHT