Leonton MPT2-0201-M Series Скачать руководство пользователя страница 9

LED Indicators 

There are LED light indicators located on the front panel of the industrial Media Converter that 
display the power status and network status. Each LED indicator has a different color and has its 
own specific meaning, see below in Table 2.4.

 

LED

 

Color

 

Description

 

P1

 

Green

 

On

 

Power input 1 is active

 

Off

 

Power input 1 is inactive

 

P2

 

Green

 

On

 

Power input 2 is active

 

Off

 

Power input 2 is inactive

 

Fault 

Red

 

On

 

Power input 1 or 2 is inactive or Port link failed

 

Off

 

Power input 1 and 2 are both functional and Port link 
correct

 

LAN Port 

(LINK/ACT)

 

Green

 

 

On

 

Connected to network, 10/100Mbps

 

Flashing

 

Networking is active

 

Off

 

Not connected to network

 

LAN Port 

(SPEED)

 

Green

 

 

On

 

Connected to network at 100Mbps

 

Off

 

Connected to network at 10Mbps

 

100FX Fiber Port 

(LINK/ACT) 

Green 

On

 

Connected to network, 100Mbps

 

Flashing

 

Networking is active

 

Off

 

Not connected to network

 

PoE

 

Green

 

On

 

The port is supplying power to the powered-device

 

Off

 

No powered-device attached or power supplying fails

 

Table 2.4: LED Indictors for MPT2-0201-M Series 

 
NOTE:

 "P1/P2" is the abbreviation for "Power1/Power2", "ACT" is for "Activity", and "L/A" is for 

"Link/Activity". 

 

 

 

Содержание MPT2-0201-M Series

Страница 1: ...Leonton MPT2 0201 M Series MPT2 0201 M MPT2 0201 M T User Manual Version 1 0...

Страница 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Страница 3: ...the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Страница 4: ...el 4 Top View 4 LED Indicators 5 DIP Switch Setting 6 Ethernet Ports 7 Fiber Port 8 Cabling 8 Wiring the Power Inputs 9 Wiring the Fault Alarm Contact 10 Grounding Note 10 Mounting Installation 11 DIN...

Страница 5: ...needs for industrial automation application and harsh environments Key Features Interface Performance Copper port support auto MDI MDI X function Embedded 1 10 100Tx PSE 30W port and 1 100Fx SC ST ty...

Страница 6: ...a protection device on the power supply input Supply by UL Listed industrial use power The industrial Media Converter s hardware specs ports cabling information and wiring installation will be describ...

Страница 7: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of MPT2 0201 M series W x H x D is 26mm x 95mm x 75mm Figure 2 1 MPT2 0201 M Series Physical Dimensions...

Страница 8: ...low in Figure 2 2 Figure 2 2 The Front Panel of MPT2 0201 M Series Top View Figure 2 3 below shows the top panel of the MPT2 0201 M series Media Converter that is equipped with one 6 pin removal termi...

Страница 9: ...ailed Off Power input 1 and 2 are both functional and Port link correct LAN Port LINK ACT Green On Connected to network 10 100Mbps Flashing Networking is active Off Not connected to network LAN Port S...

Страница 10: ...mode default DIP Switch 3 ON Set Fiber Port at Half Duplex OFF Set Fiber Port at Full Duplex default DIP Switch 4 ON Disable Auto negotiation on Copper Port OFF Enable Auto negotiation on Copper Port...

Страница 11: ...raight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 6 1000BASE T RJ 45...

Страница 12: ...is a Class 1 Laser LED product that complies with IEC 60825 1 Don t stare into the Laser LED Beam Cabling Use the four twisted pair category 5e or the above cabling for RJ 45 port connections The cabl...

Страница 13: ...on the terminal block connector as shown below in Figure 2 9 Figure 2 9 Power Terminal Block Step 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 10 Fig...

Страница 14: ...the Fault Alarm Contact Caution The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault a...

Страница 15: ...and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Media Converter Step 1 Use the screws to install the DIN Rail bracket on the rear side of the industrial Media Converte...

Страница 16: ...ull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Media Converter on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the indus...

Страница 17: ...wall mounting brackets on the top and bottom of the industrial Media Converter Step 3 Use the screws to screw the wall mounting bracket on the industrial Media Converter Caution The torque for tighte...

Страница 18: ...14 Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mounting Bracket Dimensions...

Страница 19: ...he power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication Step 5 Pre...

Страница 20: ...l as other cables Be careful when handling them so as to not trip over Do not under any circumstance insert foreign objects of any kind into the heat dissipation holes located in the different faces o...

Страница 21: ...n identifying problems the Media Converter can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indicat...

Отзывы: