FCC Notice

 

This equipment has been tested and found to comply with the limits for a Class-A digital device, 
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates, uses, and can 
radiate radio frequency energy. It may cause harmful interference to radio communications if the 
equipment is not installed and used in accordance with the instructions. However, there is no 
guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of 
the following measures:

 

 

Reorient or relocate the receiving antenna.

 

 

Increase the separation between the equipment and receiver.

 

 

Connect the equipment into an outlet on a circuit different from that to which the receiver 

is connected.

 

 

Consult the dealer or an experienced radio/TV technician for help.

 

 

 

Caution: Any changes or modifications not expressly approved by the grantee of this device could 
void the user's authority to operate the equipment.

 

 

 

CE Mark Warning

 

This is a Class-A product. In a domestic environment this product may cause radio interference in 
which case the user may be required to take adequate measures.

 

 

 

This document is the current official release manual. Please check our website (www.leonton.com) 
for any updated manual or contact us by e-mail ([email protected]).

 

Содержание MPT2-0201-M Series

Страница 1: ...Leonton MPT2 0201 M Series MPT2 0201 M MPT2 0201 M T User Manual Version 1 0...

Страница 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Страница 3: ...the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Страница 4: ...el 4 Top View 4 LED Indicators 5 DIP Switch Setting 6 Ethernet Ports 7 Fiber Port 8 Cabling 8 Wiring the Power Inputs 9 Wiring the Fault Alarm Contact 10 Grounding Note 10 Mounting Installation 11 DIN...

Страница 5: ...needs for industrial automation application and harsh environments Key Features Interface Performance Copper port support auto MDI MDI X function Embedded 1 10 100Tx PSE 30W port and 1 100Fx SC ST ty...

Страница 6: ...a protection device on the power supply input Supply by UL Listed industrial use power The industrial Media Converter s hardware specs ports cabling information and wiring installation will be describ...

Страница 7: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of MPT2 0201 M series W x H x D is 26mm x 95mm x 75mm Figure 2 1 MPT2 0201 M Series Physical Dimensions...

Страница 8: ...low in Figure 2 2 Figure 2 2 The Front Panel of MPT2 0201 M Series Top View Figure 2 3 below shows the top panel of the MPT2 0201 M series Media Converter that is equipped with one 6 pin removal termi...

Страница 9: ...ailed Off Power input 1 and 2 are both functional and Port link correct LAN Port LINK ACT Green On Connected to network 10 100Mbps Flashing Networking is active Off Not connected to network LAN Port S...

Страница 10: ...mode default DIP Switch 3 ON Set Fiber Port at Half Duplex OFF Set Fiber Port at Full Duplex default DIP Switch 4 ON Disable Auto negotiation on Copper Port OFF Enable Auto negotiation on Copper Port...

Страница 11: ...raight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 6 1000BASE T RJ 45...

Страница 12: ...is a Class 1 Laser LED product that complies with IEC 60825 1 Don t stare into the Laser LED Beam Cabling Use the four twisted pair category 5e or the above cabling for RJ 45 port connections The cabl...

Страница 13: ...on the terminal block connector as shown below in Figure 2 9 Figure 2 9 Power Terminal Block Step 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 10 Fig...

Страница 14: ...the Fault Alarm Contact Caution The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault a...

Страница 15: ...and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Media Converter Step 1 Use the screws to install the DIN Rail bracket on the rear side of the industrial Media Converte...

Страница 16: ...ull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Media Converter on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the indus...

Страница 17: ...wall mounting brackets on the top and bottom of the industrial Media Converter Step 3 Use the screws to screw the wall mounting bracket on the industrial Media Converter Caution The torque for tighte...

Страница 18: ...14 Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mounting Bracket Dimensions...

Страница 19: ...he power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication Step 5 Pre...

Страница 20: ...l as other cables Be careful when handling them so as to not trip over Do not under any circumstance insert foreign objects of any kind into the heat dissipation holes located in the different faces o...

Страница 21: ...n identifying problems the Media Converter can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indicat...