Leonton MET2-0201-M Series Скачать руководство пользователя страница 10

DIP-Switch Setting 

 

There are 6  pins on  DIP-switch  on the front panel for setting  LFP  (Link Fault Pass) function  and 
Transmission control setup. The default setting for all DIP switches is “OFF.” See the Table 2.5 and 
description below for more details. 

Table 2.5: DIP-switch setting for MET2-0201-M Series 

DIP Switch 1  

ON: Enable Link Fault Pass Through 
OFF: Disable Link Fault Pass Through (default) 

DIP Switch 2  

ON: Enable “Converter mode” is to forward a frame immediately without storing in memory. 

When enable this mode, please make sure both Ethernet copper port and optic fiber port 
work at 100Mbps and Full-Duplex 

OFF: Enable “Store-and-Forward switch mode” (default) 

DIP Switch 3 

ON: Set Fiber Port at Half-Duplex 
OFF: Set Fiber Port at Full-Duplex (default) 

DIP Switch 4 

ON: Disable Auto-negotiation on Copper Port 
OFF: Enable Auto-negotiation on Copper Port (default) 

DIP Switch 5 

ON: Set Copper Port transmission speed at 10Mbps 
OFF: Set Copper Port transmission speed at 100Mbps (default) 

DIP Switch 6 

ON: Set Copper Port transmission speed at Half-Duplex 
OFF: Set Copper Port transmission speed at Full-Duplex (default) 

 

 

Caution

: If changing the current DIP-switch setting, the device should be power off and 

then power on again to make the setting effective. 

DIP-Switch  

1  

2  

Fiber Port 

Setting 

Copper Port Settings 

 

 

 

 

ON

 

LFP Enable

 

Converter Mode

 

Half-Duplex 

Mode

 

Auto-negotiation 

Disable

 

10Mbps

 

Half-Duplex 

Mode

 

OFF

 

LFP Disable

 

Switch Mode

 

Full-Duplex 

Mode

 

Auto-negotiation 

Enable

 

100Mbps

 

Full-Duplex 

Mode

 

Содержание MET2-0201-M Series

Страница 1: ...Leonton MET2 0201 M Series MET2 0201 M MET2 0201 M T User Manual Version 1 0...

Страница 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Страница 3: ...the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Страница 4: ...el 4 Top View 4 LED Indicators 5 DIP Switch Setting 6 Ethernet Ports 7 Fiber Port 8 Cabling 8 Wiring the Power Inputs 9 Wiring the Fault Alarm Contact 10 Grounding Note 10 Mounting Installation 11 DIN...

Страница 5: ...industrial automation application and harsh environments Key Features Interface Performance Copper port support auto MDI MDI X function Embedded 1 10 100Tx Fast Ethernet and 1 100Fx SC ST type connec...

Страница 6: ...a protection device on the power supply input Supply by UL Listed industrial use power The industrial Media Converter s hardware specs ports cabling information and wiring installation will be describ...

Страница 7: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of MET2 0201 M series W x H x D is 26mm x 95mm x 75mm Figure 2 1 MET2 0201 M Series Physical Dimensions...

Страница 8: ...low in Figure 2 2 Figure 2 2 The Front Panel of MET2 0201 M Series Top View Figure 2 3 below shows the top panel of the MET2 0201 M series Media Converter that is equipped with one 6 pin removal termi...

Страница 9: ...Fault Red On Power input 1 or 2 is inactive or Port link failed Off Power input 1 and 2 are both functional and Port link correct LAN Port LINK ACT Green On Connected to network 10 100Mbps Flashing N...

Страница 10: ...mode default DIP Switch 3 ON Set Fiber Port at Half Duplex OFF Set Fiber Port at Full Duplex default DIP Switch 4 ON Disable Auto negotiation on Copper Port OFF Enable Auto negotiation on Copper Port...

Страница 11: ...raight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 6 1000BASE T RJ 45...

Страница 12: ...is a Class 1 Laser LED product that complies with IEC 60825 1 Don t stare into the Laser LED Beam Cabling Use the four twisted pair category 5e or the above cabling for RJ 45 port connections The cabl...

Страница 13: ...on the terminal block connector as shown below in Figure 2 9 Figure 2 9 Power Terminal Block Step 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 10 Fig...

Страница 14: ...the Fault Alarm Contact Caution The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault a...

Страница 15: ...and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Media Converter Step 1 Use the screws to install the DIN Rail bracket on the rear side of the industrial Media Converte...

Страница 16: ...ull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Media Converter on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the indus...

Страница 17: ...wall mounting brackets on the top and bottom of the industrial Media Converter Step 3 Use the screws to screw the wall mounting bracket on the industrial Media Converter Caution The torque for tighte...

Страница 18: ...14 Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mounting Bracket Dimensions...

Страница 19: ...he power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication Step 5 Pre...

Страница 20: ...l as other cables Be careful when handling them so as to not trip over Do not under any circumstance insert foreign objects of any kind into the heat dissipation holes located in the different faces o...

Страница 21: ...n identifying problems the Media Converter can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indicat...

Отзывы: