Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 11.0 EN · 04/2016 · TD17
103
14
Parameter reference
14.3
Parameters of the communication module for slot MXI2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14002
C14003
C14010
C14011
Parameter | Name:
C14002 | Gateway address
Data type: UNSIGNED_32
Index: 10573 = 0x294D
Setting of the gateway address
Setting the IP configuration (
Setting range
(min. value | unit | max. value)
Lenze setting
0
4294967295
0
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14003 | MAC ID
Data type: OCTET_STRING
Index: 10572 = 0x294C
Display of the MAC-ID
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14010 | Active IP address
Data type: UNSIGNED_8
Index: 10565 = 0x2945
Display of the active IP address
The active IP address may differ from the contents of code
, depending on whether the station name was
changed via the fieldbus or the parameter (
).
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C14010/1
Active IP address.1
C14010/2
Active IP address.2
C14010/3
Active IP address.3
C14010/4
Active IP address.4
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14011 | Active subnetwork mask
Data type: UNSIGNED_8
Index: 10564 = 0x2944
Display of the active subnetwork mask
The active subnet mask may differ from the contents of code
, depending on whether the station name was
changed via the fieldbus or the parameter (
).
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C14011/1
Active subnetwork mask.1
C14011/2
Active subnetwork mask.2
C14011/3
Active subnetwork mask.3
C14011/4
Active subnetwork mask.4
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT