10.5
Process output data (CiA 402 objects)
Parameter
Address
Name / setting range / [default setting]
Info
0x2831
Inverter-Statuswort
•
Read only
Bit coded status word of the internal motor control.
Bit 1 Speed setpoint 1 limited
1 ≡ input of speed controller 1 in limitation.
Bit 2 Speed controller in limitation
1 ≡ output of speed controller 1 in limitation.
Bit 3 Torque setpoint limited
1 ≡ setpoint torque in limitation.
Bit 4 Soll-Q-Strom limitiert
1 ≡ setpoint current in limitation.
Bit 5 Speed setpoint 2 limited
1 ≡ input of the speed controller 2 in "torque mode" in limitation.
Bit 6 Obere Drehzahlgrenze aktiv
1 ≡ in "torque mode", the speed is limited to upper speed limit
.
Bit 7 Untere Drehzahlgrenze aktiv
1 ≡ in "torque mode", the speed is limited to lower speed
limit
Bit 10 Output frequency limited
1 ≡ setpoint frequency with V/f operation in limitation.
Bit 11 Magnetisation completed
1 ≡ during V/f operation, the factor 7 rotor time constant has passed
(calculated from the time at which the inverter was enabled without
restart on the fly and with a total motor current of 20 % rated motor cur-
rent for the first time). Otherwise 0.
Bit 12 Motorphasenfehler
1 ≡ motor phase failure detection active.
Bit 14 Error reset blocking time active
1 ≡ the fault can only be reset when the blocking time has elapsed.
0x603F
Error code
•
Read only
Error message
Bit 0
0x6041
CiA: Statusword
•
Read only
Mappable CiA 402 status word with bit assignment according to device
profile CiA 402.
Bit 0 Ready to switch on
1 ≡ drive ready to start
Bit 1 Switched on
1 ≡ drive switched-on
Bit 2 Operation enabled
1 ≡ operation enabled
Bit 3 Fault
1 ≡ fault or trouble active
Bit 4 Voltage enabled
1 ≡ DC bus ready for operation
Bit 5 Quick stop
0 ≡ quick stop active
Bit 6 Switch on disabled
1 ≡ operation inhibited
Bit 7 Warning
1 ≡ warning active
Bit 8 RPDOs deactivated
1 ≡ cyclic PDOs have been deactivated.
Bit 9 Remote
1 ≡ inverter can receive commands via network.
•
Bit is not set in the operating mode
= "MS: Velocity mode
[-2]".
Bit 10 Target reached
1 ≡ the actual position is in the window.
Bit 11 Internal limit active
1 ≡ internal limitation of a setpoint active.
Bit 12 Operation mode active
1 ≡ operation enabled and no test mode activated. (no internal setpoint
generation active.)
Bit 13 Following error
1 ≡ following error active
Bit 14 Holding brake released
1 ≡ holding brake released
Bit 15 Integrated safety not active
0 ≡ the inverter has been disabled by the integrated safety system
1 ≡ the integrated safety system is not active
0x6061
Modes of operation display
•
Read only
Display of the current operating mode.
-11 Identification
-10 Test mode
0 No mode change/no mode assigned
No operating mode (standstill)
2 CiA: Velocity mode
CiA 402 velocity mode
8 Cyclic sync position mode
9 Cyclic sync velocity mode
10 Cyclic sync torque mode
0x6043
Velocity demand
•
Read only: x rpm
Display of the setpoint velocity (velocity mode).
Configure speed control
Process output data (CiA 402 objects)
185
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......