9.6.7
Extension for the digital inputs DI3 and DI4
The content of this section is currently being processed.
Parameter
Address
Name / setting range / [default setting]
Info
0x2D02:001
Touch probe diagnostics: Touch probe 3/4 function
0x0000 ... [0x0000] ... 0xFFFF
Bit 0 Activate touch probe 3
Bit 1 Touch probe 3 trigger = 1st event/continous
Bit 2 Touch probe 3 source = TP input/zero pulse
Bit 4 Touch probe 3 sampling = rising edge
Bit 5 Touch probe 3 sampling = falling edge
Bit 6 Position feedback source
Bit 8 Activate touch probe 4
Bit 9 Touch probe 4 trigger = 1st event/continous
Bit 10 Touch probe 4 source = TP input/zero pulse
Bit 12 Erfassung Touch-Probe 4 = steigende Flanke
Bit 13 Erfassung Touch-Probe 4 = fallende Flanke
Bit 14 Position feedback source
0x2D02:002
Touch probe diagnostics: Touch-Probe 3/4 status
•
Read only
Bit 0 Touch-Probe 3 ist aktiviert
Bit 1 Touch-Probe 3 - Position erfasst fallende
Flanke
Bit 2 Touch-Probe 3 - Position erfasst steigende
Flanke
Bit 6 Touch-Probe 3 - Pegel bei Zeitstempel
Bit 8 Touch-Probe 4 ist aktiviert
Bit 9 Touch-Probe 4 - Position erfasst fallende
Flanke
Bit 10 Touch-Probe 4 - Position erfasst steigende
Flanke
Bit 14 Touch-Probe 4 - Pegel bei Zeitstempel
0x2D03:001
Touch probe position: Touch probe 3 position rising
edge
•
Read only: x pos. unit
0x2D03:002
Touch probe position: Touch probe 3 position falling
edge
•
Read only: x pos. unit
0x2D03:003
Touch probe position: Touch probe 4 position rising
edge
•
Read only: x pos. unit
0x2D03:004
Touch probe position: Touch probe 4 position falling
edge
•
Read only: x pos. unit
9.6.8
Detected time stamp and positions
In case of the "continuous touch probe configuration", a newly detected value
overwrites the previously detected value.
Parameter
Address
Name / setting range / [default setting]
Info
0x2D01:001
Touch probe (TP) time stamp: Touch probe 1-rising
edge time stamp
•
Read only: x ns
Display of the time stamp of the rising edge for touch probe 1.
0x2D01:002
Touch probe (TP) time stamp: Touch probe 1-falling
edge time stamp
•
Read only: x ns
Display of the time stamp of the falling edge for touch probe 1.
Configure position control
Position detection with touch probe (TP)
Extension for the digital inputs DI3 and DI4
169
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......