9.6.5
Touch probe control word
Control word for configuring the touch probe functionality.
Parameter
Address
Name / setting range / [default setting]
Info
0x60B8
Touch probe function
0x0000 ... [0x0000] ... 0xFFFF
Control word for configuring the touch probe functionality.
Bit 0 Enable touch probe 1
0: deactivate touch probe channel 1.
1: activate touch probe channel 1.
Bit 1 TP1: 1. or continous
Event for touch probe channel 1
0: only detect the first event.
1: detect all events.
Bit 2 TP1: DIx or zero pulse
Source for touch probe channel 1
0: digital input 1
1: zero pulse position encoder
Bit 4 TP1: Activate pos. edge
0: deactivate scanning.
1: activate scanning.
Bit 5 TP1: Activate neg. edge
Bit 8 Enable touch probe 2
0: deactivate touch probe channel 2.
1: activate touch probe channel 2.
Bit 9 TP2: 1. or continous
Event for touch probe channel 2
0: only detect the first event.
1: detect all events.
Bit 10 TP2: DIx or zero pulse
Source for touch probe channel 2
0: digital input 2
1: zero pulse position encoder
Bit 12 TP2: Activate pos. edge
0: deactivate scanning.
1: activate scanning.
Bit 13 TP2: Activate neg. edge
9.6.6
Touch probe status word
Status word of the touch probe functionality.
Parameter
Address
Name / setting range / [default setting]
Info
0x60B9
Touch probe status
•
Read only
Status of the touch probe functionality.
Bit 0 Touch-Probe 1 enabled
0: touch probe channel 1 deactivated.
1: touch probe channel 1 activated.
Bit 1 TP1: Pos. edge detected
0: position not detected.
1: position detected.
Bit 2 TP1: Neg. edge detected
Bit 6 TP1: Detected level
Level for detection via touch probe channel 1
0: LOW level
1: HIGH level
Bit 8 Touch-Probe 2 enabled
0: touch probe channel 2 deactivated.
1: touch probe channel 2 activated.
Bit 9 TP2: Pos. edge detected
0: position not detected.
1: position detected.
Bit 10 TP2: Neg. edge detected
Bit 14 TP2: Detected level
Level for detection via touch probe channel 2
0: LOW level
1: HIGH level
Configure position control
Position detection with touch probe (TP)
Touch probe status word
168
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......