Safety information

Lenze controllers

1

l

EDK82EVXXX EN 2.0

1

Safety information

1.1

Safety and application notes for Lenze controllers

(in conformity with the Low-Voltage Directive 73/23/EEC)

General

Lenze controllers (frequency inverters, servo inverters, DC controllers) can include live and rotating
parts - depending on their type of protection - during operation. Surfaces can be hot.

Non-authorized removal of the required cover, inappropriate use, incorrect installation or operation,
creates the risk of severe injury to persons or damage to material assets.

For more detailed information please see the documentation.

All operations concerning transport, installation, and commissioning as well as maintenance must
be carried out by qualified, skilled personnel (IEC 364 or CENELEC HD 384 or DIN VDE 0100 and
IEC report 664 or DIN VDE 0110 and national regulations for the prevention of accidents must be
observed).

According to this basic safety information qualified skilled personnel are persons who are familiar
with the installation, assembly, commissioning, and operation of the product and who have the
qualifications necessary for their occupation.

Application as directed

Drive controllers are components which are designed for installation in electrical systems or
machinery. They are not to be used as household appliances. They are intended exclusively for
professional and commercial purposes according to EN 61000-3-2. This documentation includes
information in compliance with the EN 61000-3-2.

When installing the drive controllers in machines, commissioning (i.e. starting of operation as
directed) is prohibited until it is proven that the machine complies with the regulations of the EC
Directive 98/37/EC (Machinery Directive); EN 60204 must be observed.

Commissioning (i.e. starting of operation as directed) is only allowed when there is compliance with
the EMC Directive (89/336/EEC).

The drive controllers meet the requirements of the Low-Voltage Directive 73/23/EEC. The
harmonised standards of the series EN 50178/DIN VDE 0160 apply to the controllers.

The technical data and information on the connection conditions must be obtained from the
nameplate and the documentation. They must be observed in any case.

Warning: The availability of controllers is restricted according to EN 61800-3. These products can
cause radio interferences in residential areas. In this case, special measures are required.

Transport, storage

Please observe the notes on transport, storage and appropriate handling.

Observe the climatic conditions according to EN 50178.

Содержание Global Drive 8200 vector

Страница 1: ...L Information for the operator of the machine system EDK82EVXXX P2F Global Drive 8200 vector frequency inverter 0 25 90 kW P2F...

Страница 2: ...kW Inverter Input Output 8200 vector Type _ K For detailed information refer to the manual EDK82EV222 Id No Made in Germany 1D74 Industrial Control Equipment D 31855 Aerzen Hans Lenze Str 1 Prod No Se...

Страница 3: ...Drive controllers are components which are designed for installation in electrical systems or machinery They are not to be used as household appliances They are intended exclusively for professional a...

Страница 4: ...ry adapt the controllers to your application Please observe the corresponding information given in the Instructions After the controller has been disconnected from the supply voltage live components a...

Страница 5: ...be used as safety brakes It cannot be guaranteed that factors which cannot be influenced such as oil ingression because of a defective A side shaft seal do not cause a torque reduction Transport stora...

Страница 6: ...and the box itself must be sealed against dust and water For the trial run without output elements lock the key Check brakeoperation before commissioning of low voltage machines with brakes Operation...

Страница 7: ...heatsink of the controller has an operating temperature of 80 C Direct skin contact with the heatsink results in burnings Controller protection z All pluggable connection terminals must only be conne...

Страница 8: ...graph Signal word Possible consequences if the safety information are Signal word Meaning safety information are disregarded Danger Impending danger for persons Death or most severe injuries Dangerous...

Страница 9: ...f k i h PS m n op q r Hi Hz sh rpm C m A V Lo z y w x v t u s 88800 0050000 1 a b c d e j g f k i h PS m n op q r Hi Hz sh rpm C m A V Lo 88888 8888888 8 a b c d e j g f k i h PS m n op q r Hi Hz sh r...

Страница 10: ...bcode number 2 Change the parameter value of a sub code Five digit display of the current value 1 Display of values longer than 5 digits 1 H high order positions Display HI L low order positions Displ...

Страница 11: ...igital signals must be used to activate a parameter set for operation configuration with C0410 z In the function 0 the display shows the parameter set which is just active during operation Step Keys R...

Страница 12: ...quency Display Output frequency without slip compensation C0034 Setpoint selection range 0 Standard I O X3 8 0 5 V 0 10 V 0 20 mA C0034 Setpoint selection range 0 Application I O X3 1U 0 5 V 0 10 V X3...

Страница 13: ...Lo 1 j g f k i h PS 001 0 000 000 a b c d e m n op q r Hi Hz Lo 1 j g f k i h PS 0007 000 000 a b c d e m n op q r Hi Hz Lo 1 j g f k i h PS 0034 z y w x v t u s 000 000 a b c d e m n op q r Hi Hz Lo...

Страница 14: ...ect configuration in C0410 Use internal voltage source X3 20 for function modules Standard I O INTERBUS PROFIBUS DP or LECOM B RS485 Bridge between X3 7 and X3 39 is missing Bridge terminals Motor doe...

Страница 15: ...r active check under C0161 OFF 20 28 X3 880Hr 01 61 000 1 a b c d e j g f k i h PS m n op q r Hi Hz sh rpm C m A V Lo 3 1 4 5 2 6 ON z y w x v t u s 88888 8888888 8 a b c d e j g f k i h PS m n op q r...

Страница 16: ...us configuration For operation with application I O Faulty parameter setting of parameter set changeover In all parameter sets the signal parameter set changeover C0410 13 C0410 14 must be combined wi...

Страница 17: ...re 80 C Impermissibly high currents or too frequent and too long acceleration Check drive selection Check load if necessary replace defective bearings OH3 53 PTC monitoring TRIP is displayed if C0119...

Страница 18: ...to TRIP reset More than 8 fault messages in 10 minutes Depends on the error message sd5 85 Wire breakage analog input 1 Current at analog input 4 mA at setpoint range 4 20 mA Close circuit at analog i...

Отзывы: