Commissioning
5-4
BA9300SU EN 2.1
5.2
Input of the motor data
To achieve an optimum speed-torque behaviour of the drive, it is necessary to enter the nameplate
data of the connected motor.
•
If a LENZE motor is used:
– Select the motor type under C0086 (see Chapter 11.3; Code table or Chapter 11.5; Motor
selection list). The controller sets all other motor data automatically.
– To achieve outstanding accuracy you can enter the eight-digit designation of the motor
nameplate ” Geber” (encoder” ) under C0416 when using motors with resolvers (optional).
•
If the motor type is not listed under C0086, select a similar Lenze motor under C0088 C0086
(see Chapter 11.3; Code table or Chapter 11.5; Motor selection list). You have to change the
following motor data manually:
– C0006: Operating mode of the motor control
– C0022: Adapt I
max
to the maximum motor current
– C0081: Rated motor power
– C0087: Rated motor speed
– C0088: Rated motor current
– C0089: Rated motor frequency
– C0090: Rated motor voltage
– C0091: Motor-cos
ϕ
– User-specific detection of the motor temperature (see Chapter 4.2.9)
Only for very high requirements to the control features:
– C0084: Stator resistance of the motor
– C0085: Leakage inductance of the motor
Note!
•
All required inputs are contained in the menu ” Motor/feedb.” (Motor/feedback system” ).
•
If you select a motor type under C0086 and change one of the above listed motor data
subsequently, C0086 = o (COMMON) is set (i.e. no Lenze motor is used).
•
Do not operate reluctance motors.
Содержание EVS9321-CS
Страница 3: ...Operating Instructions EDB9300UES 00414796 Global Drive 9300 servo ...
Страница 21: ...Technical data 3 8 BA9300SU EN 2 1 ...
Страница 57: ...Installation 4 36 BA9300SU EN 2 1 ...
Страница 73: ...During operation 6 4 BA9300SU EN 2 1 ...
Страница 117: ...Troubleshooting and fault elimination 9 10 BA9300SU EN 2 1 ...
Страница 119: ...Maintenance 10 2 BA9300SU EN 2 1 ...
Страница 188: ...Appendix 11 69 BA9300SU EN 2 1 ...
Страница 189: ...Appendix 11 70 BA9300SU EN 2 1 ...